DEHYDRATION OF ACETIC ACID BY PERVAPORATION Materid Science Aspects
نویسندگان
چکیده
PROEFSCHRIFI' ter verkrijging van de graad van doctor aan de Universiteit Twente, op gezag van de rector magnificus, volgens besluit van het College van Dekanen in het openbaar te verdedigen op vrijdag 26 juni 1992 te 14.00 uur prof. dr. 3 ACKNOWLEDGEMENT The work described in this thesis is part of the Brite-project NIB-196. B.P. Chemicals Ltd, Deutsche Carbone GmbH Geschäftseinheit GFT and the universities of Köln and Aachen are gratefully acknowledged for the pleasant cooperation , The European Community (BIUTE), B.P. Chemicals Ltd and Deutsche Carbone GmbH Geschäftseinheit GFT are also gratefully acknowledged for their financial support.
منابع مشابه
Acetic acid Separation as a Function of Temperature Using Commercial Pervaporation Membrane
Acetic acid was separated from a dilute mixture using a commercial polyvinyl alcohol (PVA) membrane. Intrinsic separation characteristics of the membrane were studied as a function of temperature. The degree of membrane swelling decreased marginally with increase in feed temperature. At 25oC the maximum degree of swelling was found out to be 46.3%, which reduced to 39.5%...
متن کاملFabrication of Crosslinkable Hollow Fiber Membranes for Pervaporation Dehydration
Integrally-skinned asymmetric Polyetherimide/Poly (vinyl alcohol) (PEI/PVA) hollow fber membranes for pervaporation dehydration were fabricated by non-solvent induced phase inversion. PVA inside the PEI matrix could be crosslinked to provide membrane performance stability during long term operation. The effects of different PEI/PVA blend ratio, external coagulant type and...
متن کاملSelectivity as a Function of Membrane Thickness: Gas Separation and Pervaporation
In this article, the pervaporation selectivity as a function of the membrane thickness is studied for the dehydration of acetic acid. From this study, it appeared that the selectivity of polysulfone (PSF) , poly (vinyl chloride) (PVC ) , and polyacrylonitrile (PAN) decreases with decreasing membrane thickness, below a limiting value of about 15 pm. However, in the case of gas separation, the se...
متن کاملEFFECT OF OPERATING CONDITIONS ON THE DEHYDRATION OF TOLUENE BY PERVAPORATION USING A POLYVINYL ALCOHOL MEMBRANE
The effects of operating parameters such as feed temperature and permeate-side pressure on the performance of a commercial PVA membrane in the dehydration of toluene by a pervaporation (PV) membrane system is studied in the present work. The results obtained indicate that increasing temperature in the range of 40 to 70 °C and reducing permeate pressure in the range of 1 to 10 mmHg increase memb...
متن کاملComparison of the Separation Characteristics of Polyvinyl Alcohol Membrane in Dehydration of Benzene and Toluene Using Pervaporation
Pervaporation (PV) is a well-established membrane technique used in separation; especially dehydration of organic solvents. Along with other parameters such as permeate pressure and feed temperature; feed composition is an important parameter, which affects separation characteristics and membrane performance in pervaporation. In this paper, the separation characteristics of a hydrophilic polyvi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2000