Use of subclavian vein for permanent cardiac pacing.

نویسندگان

  • G P McNeill
  • N C Taylor
چکیده

The subclavian vein has been used to implant permanent pacing catheters in 40 patients with symptomatic heart block. Though the cephalic and external jugular veins are usually preferred for this purpose in Britain, the use of these veins has certain disadvantages. In this study subclavian venepuncture by the infraclavicular approach was performed without diffculty and found to be a safe procedure. Three months after implantation, 7.5 per cent of patients had developed catheter tip dislocation and 87.5 per cent of patients were entirely free of complications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of endocardial leads for permanent cardiac pacing.

Catheter tip dislocation is the main complication of permanent pacemaker implantation using the subclavian vein. In this study of 50 patients we compared the incidence of complications using two endocardial electrodes specially designed to prevent tip dislocation. One catheter had a helical endocardial electrode and the other had retractable nylon barbs. The helical electrode was superior in ev...

متن کامل

A Potential Complication of Transvenous Pacemaker Electrodes

Pervenous endocardial pacing using a self-contained, totally implantable system was popularized in this country by Chardack’ in 1965 and subsequently has become the established mode of permanent pacing. Although this intervention may be lifesaving, it is not without risk. Occlusion of major vessels incited by the presence ofa pacing electrode is an extremely rare occurrence. We describe four pa...

متن کامل

Occlusion of the proximal subclavian vein complicating pacemaker lead implantation.

A set of images in which a pacemaker lead replacement procedure was complicated by occlusion of the proximal subclavian vein is presented. However, this was not detected on venography performed before the procedure. Physicians should be aware of a more proximal occlusion of the subclavian vein while replacing pacemaker leads, even in cases with seemingly normal venography.

متن کامل

Twenty-Seven Years Experience With Transvenous Pacemaker Implantation in Children Weighing <10 kg.

BACKGROUND Epicardial pacemaker implantation is the favored approach in children weighing <10 kg in many units. The high incidence of premature failure and fractures with earlier epicardial leads led our unit to undertake transvenous pacemaker implantation in neonates and infants from 1987. To date there have been no long-term follow-up reports of what is for many a controversial strategy. ME...

متن کامل

Temporary cardiac pacing at the bedside.

The equipment required are (1) a bedside cardiac monitor (2) a defibrillator (3) an ECG machine preferably powered by battery (4) three crocodile clips (5) external pulse generator (6) temporary pacing electrodes and (7) a cutdown set. The cutdown set may include various cannulae introducer systems. We are only describing here the system where the cannula supplied with the temporary electrodes ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British heart journal

دوره 40 2  شماره 

صفحات  -

تاریخ انتشار 1978