Direct identification of gram-positive cocci from routine blood cultures by using AccuProbe tests.

نویسندگان

  • Laura Lindholm
  • Hannu Sarkkinen
چکیده

Rapid and reliable identification of bacteria directly from blood cultures is important in clinical practice to guide appropriate antibiotic therapy. In this study, the performance of the AccuProbe (Gen-Probe, Inc., San Diego, Calif.) in direct identification of Staphylococcus aureus, Streptococcus pneumoniae, enterococci, and group A and B streptococci from positive blood culture bottles was evaluated by using 6-year routine clinical laboratory blood culture material from Paijat-Hame Central Hospital, Lahti, Finland. With the enterococcal and group A and B streptococcal probes, the diagnostic performance of the test was excellent at a cutoff value of 50,000 relative light units (RLU) as recommended by the manufacturer. However, with the S. aureus probe, although the specificity was very high (99.8%), the sensitivity was low (72.4%). To improve the clinical usability of the direct AccuProbe identification, optimal cutoff values for the individual AccuProbe tests were defined by using receiver-operating characteristic analysis. Consequently, cutoff values for S. aureus and S. pneumoniae tests were adjusted to 30,000 RLU and for enterococci and to 55,000 RLU for group A and B streptococci. With these adjustments, the performance of the AccuProbe tests, especially that for S. aureus, was significantly improved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of three rapid methods for the direct identification of Staphylococcus aureus from positive blood cultures.

Staphylococci represent the most commonly encountered blood culture isolates. Differentiating Staphylococcus aureus from coagulase-negative staphylococci (CoNS) is important in guiding empirical therapy, especially since the majority of CoNS are contaminants. This study evaluated three rapid methods for the direct identification of S. aureus from blood cultures. A total of 157 patient blood cul...

متن کامل

Efficacy of direct Gram stain in differentiating staphylococci from streptococci in blood cultures positive for gram-positive cocci.

A preponderance of clusters seen on direct Gram stain of blood cultures positive for gram-positive cocci was 98% sensitive and 100% specific for identification of staphylococcal species or of Peptococcus. A preponderance of chains, pairs, or both was 100% sensitive and 98% specific for identifying streptococci. Further presumptive identification of either staphylococci or streptococci based on ...

متن کامل

Evaluation of the Hyplex BloodScreen Multiplex PCR-Enzyme-linked immunosorbent assay system for direct identification of gram-positive cocci and gram-negative bacilli from positive blood cultures.

We evaluated the Hyplex BloodScreen PCR-enzyme-linked immunosorbent assay (ELISA) system (BAG, Lich, Germany), a new diagnostic test for the direct identification of gram-negative bacilli and gram-positive cocci from positive blood cultures, with 482 positive BACTEC 9240 blood culture bottles. The test involves amplification of the bacterial DNA by multiplex PCR and subsequent hybridization of ...

متن کامل

Evaluation of rapid identification of gram-positive cocci in positive blood cultures by use of the AutoMicrobic system Gram-Positive Identification Card.

Because rapid identification of gram-positive organisms from blood cultures may provide valuable information for patient care and because the AutoMicrobic system Gram-Positive Identification (AMS-GPI) Card (Vitek Systems, Inc., Hazelwood, Mo.) is designed for the identification of these organisms in 4 to 13 h, we designed this study to evaluate the performance of the AMS-GPI Card in the direct ...

متن کامل

Rapid identification and susceptibility testing using the VITEK 2 system using culture fluids from positive BacT/ALERT blood cultures.

BACKGROUND AND PURPOSE In order to reduce the turnaround time for laboratory diagnosis of bacteremia, the efficacy of identification and antimicrobial susceptibility testing using samples taken directly from positive BacT/ALERT standard aerobic and standard anaerobic blood culture bottles was evaluated. METHODS 160 positive blood culture bottles were examined and incubated at 35 degrees C in ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 42 12  شماره 

صفحات  -

تاریخ انتشار 2004