Main limitations of transpulmonary thermodilution: set targets

نویسندگان

  • Manuel Sánchez-Sánchez
  • Eva Herrero
  • Lucia Cachafeiro
  • Eva Flores
  • Alexander Agrifoglio
  • Belén Civantos
  • Abelardo García-de-Lorenzo
چکیده

Background We read with great interest the review by Xavier Monnet and Jean-Louis Teboul [1]. This review concluded that transpulmonary thermodilution (TPTD) provides a full haemodynamic evaluation. The authors discuss the limitations of previous studies reporting a lack of outcome improvement in patients treated using TPTD-based fluid management. They stated that the objectives of these studies were not comparable and that questionable protocols were used. Based on our previous studies of TPTD in burn patients [2], we would like to make some comments. The TPTD technique provides parameters that must be interpreted having previous knowledge about situations which may influence results. In addition, the normal values of healthy individuals may not be appropriate comparators for critically ill patients. Therefore, the successful use of this device should be based on the achievement of appropriate objectives [3]. Extravascular lung water or the pulmonary vascular permeability index can be useful parameters for reducing the fluid load if it is elevated, but not to provide more volume if it is low because the patient may not exhibit preload responsiveness or may show only ‘temporary’ responsiveness. For instance, if there is high capillary leakage, the haemodynamic benefits obtained may be lost in a short time. Furthermore, it is erroneous to equate alteration of the pulmonary vascular permeability index with the systemic vascular permeability index [4]. In any case, this technique can help determine other parameters, such as stroke volume variation, or measure the responses of these parameters to fluid challenge. In our study, we have found that critically ill patients with slightly low preload values (global end-diastolic volume < 600 ml/m) achieve adequate cardiac index (>2.5 L/min/m) and lactate values (<2 mmol/L), avoiding excessive volume contributions [2, 5]. Finally, it is important to acknowledge possible complications in certain circumstances. For example, in burn patients with severe hypovolemia we found a higher incidence of transient ischaemia in the lower limbs than the 0.4% reported in some studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Global end-diastolic volume acquired by transpulmonary thermodilution depends on age and gender in awake and spontaneously breathing patients

INTRODUCTION Volumetric parameters acquired by transpulmonary thermodilution had been repeatedly proven superior to filling pressures for estimation of cardiac preload. Up to now, the proposed normal ranges were never studied in detail. We investigated the relationship of the global end-diastolic volume (GEDV) acquired by transpulmonary thermodilution with age and gender in awake and spontaneou...

متن کامل

Transpulmonary thermodilution: advantages and limits

BACKGROUND For complex patients in the intensive care unit or in the operating room, many questions regarding their haemodynamic management cannot be answered with simple clinical examination. In particular, arterial pressure allows only a rough estimation of cardiac output. Transpulmonary thermodilution is a technique that provides a full haemodynamic assessment through cardiac output and othe...

متن کامل

Pulmonary vascular permeability index in patients with femoral venous access for transpulmonary thermodilution: a prospective observational study

Title:Pulmonary vascular permeability index and global end-diastolic volume: are the data consistent in patients with femoral venous access for transpulmonary thermodilution: a prospective observational study

متن کامل

Validation of extravascular lung water measurement by single transpulmonary thermodilution: human autopsy study

INTRODUCTION Gravimetric validation of single-indicator extravascular lung water (EVLW) and normal EVLW values has not been well studied in humans thus far. The aims of this study were (1) to validate the accuracy of EVLW measurement by single transpulmonary thermodilution with postmortem lung weight measurement in humans and (2) to define the statistically normal EVLW values. METHODS We eval...

متن کامل

Goal-directed fluid management by bedside transpulmonary hemodynamic monitoring after subarachnoid hemorrhage.

BACKGROUND AND PURPOSE Optimal monitoring of cardiac output and intravascular volume is of paramount importance for good fluid management of patients with subarachnoid hemorrhage (SAH). The aim of this study was to demonstrate the feasibility of advanced hemodynamic monitoring with transpulmonary thermodilution and to provide descriptive data early after SAH. METHODS Forty-six patients with S...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 21  شماره 

صفحات  -

تاریخ انتشار 2017