The Effect of Specimen Size on the Results of Concrete Adiabatic Temperature Rise Test with Commercially Available Equipment
نویسندگان
چکیده
In this study, adiabatic temperature rise tests depending on binder type and adiabatic specimen volume were performed, and the maximum adiabatic temperature rises and the reaction factors for each mix proportion were analyzed and suggested. The results indicated that the early strength low heat blended cement mixture had the lowest maximum adiabatic temperature rise (Q∞) and the ternary blended cement mixture had the lowest reaction factor (r). Also, Q and r varied depending on the adiabatic specimen volume even when the tests were conducted with a calorimeter, which satisfies the recommendations for adiabatic conditions. Test results show a correlation: the measurements from the 50 L specimens were consistently higher than those from the 6 L specimens. However, the Q∞ and r values of the 30 L specimen were similar to those of the 50 L specimen. Based on the above correlation, the adiabatic temperature rise of the 50 L specimen could be predicted using the results of the 6 L and 30 L specimens. Therefore, it is thought that this correlation can be used for on-site concrete quality control and basic research.
منابع مشابه
Investigating the Effect of Specimen Diameter Size on Uniaxial Compressive Strength and Elastic Properties of Travertines
Uniaxial compressive strength (UCS) and elastic properties of rocks play a major and vital role for the design of any engineering structure. The specimen diameter size is one of the main factors that influencing on UCS, elasticity modulus and Poisson’s ratio (E and υ). Here, an attempt has been made to investigate the effect of specimen diameter size on UCS, E and υ. Moreover, we studied the co...
متن کاملExperimental investigation of the strength of glass fiber-reinforced concrete exposed to high temperature
This study investigated the effects of high temperature exposure on the compressive, tensile, and flexural strengths of concrete containing glass fiber. A total of 108 cubic specimens (150 mm × 150 mm × 150 mm), cylindrical specimens (300 mm × 150 mm), and prismatic specimens (500 mm × 150 mm × 150 mm) were prepared for compressive, tensile, and flexural strength testing, respectively. The spec...
متن کاملDevelopment of Direct Sandwich ELISA test for Detection of Rotavirus in Clinical Specimen
Background and Aims: Rotaviruses are one of the main causative agents of acute viral gastroenteritis in both young human and animals. Several methods have been used for diagnosis of rotavirus infection. Most of these methods are not easily available in Iran. Methods: In our study attempt was made to develop a method which could replace the commercially imported Kit. Rota virus was purified and...
متن کاملInfluence of High Strain Rates on the Mechanical Behavior of High-Manganese Steels
In this work, dynamic mechanical properties of three high-manganese steels with TRIP/TWIP or fully TWIP characteristics are studied. High strain rate experiments in the range of true strain rates between ~500 and 1800 /s are conducted using a dynamic torsional testing setup. All the three steels show a positive strain rate sensitivity in the intermediate range of strain rates (up to 500 /s). Bu...
متن کاملStudy of effect of paste volume, water to cementitious materials and fiber dosages on rheological properties and in-situ strength of self-compacting concrete
As a vibration- free concrete, self- compacting concrete (SCC) can be easily used in the absence of consolidation, therefore; it is a good option for repairing and retrofitting concrete structures. The quality of repair layer is highly effective on a successful repair. Accordingly, in this study, factors affecting the quality of fiber-reinforced self-compacting concrete repair layer, including ...
متن کامل