Brachial plexus dose tolerance in head and neck cancer patients treated with sequential intensity modulated radiation therapy
نویسندگان
چکیده
PURPOSE We aimed to study the radiation induced brachial plexopathy in patients with head and neck squamous cell carcinoma (HNSCC) treated with Sequential Intensity Modulated Radiation Therapy (S-IMRT). METHODS AND MATERIALS This IRB approved study included 68 patients with HNSCC treated consecutively. Detailed dose volume histogram data was generated for ipsilateral and contralateral brachial plexus (BP) volumes receiving a specified dose (Vds) i.e. V50-V75 and dose in Gray covering specified percent of BP volume (Dvs) i.e. D5-D30 and maximum point doses (Dmax). To assess BP injury all patients' charts were reviewed in detail for sign and symptoms of BP damage. Post-hoc comparisons were done using Tukey-Kramer method to account for multiple significance testing. RESULTS The mean and maximum doses to BP were significantly different (p < .05) based on tumor site, nodal status and tumor stage. The mean volume to the ipsilateral BP for V50, V60, V70, and V75 were 7.01 cc, 4.37 cc, 1.47 cc and 0.24 cc, respectively. The mean dose delivered to ≤5% of ipsilateral BP was 68.70 Gy (median 69.5Gy). None of the patients had acute or late brachial plexopathy or any other significant neurological complications, with a minimum follow up of two years (mean 54 months). CONCLUSIONS In this study cohort, at a minimum of two-years follow up, the mean dose of 68.7Gy, a median dose to 69.5Gy to ≤5% of ipsilateral BP, and a median Dmax of 72.96Gy did not result in BP injury when patients were treated with S-IMRT technique. However, longer follow up is needed.
منابع مشابه
Development and validation of a standardized method for contouring the brachial plexus: preliminary dosimetric analysis among patients treated with IMRT for head-and-neck cancer.
PURPOSE Although Radiation Therapy Oncology Group protocols have proposed a limiting dose to the brachial plexus for patients undergoing intensity-modulated radiotherapy for head-and-neck cancer, essentially no recommendations exist for the delineation of this structure for treatment planning. METHODS AND MATERIALS Using anatomic texts, radiologic data, and magnetic resonance imaging, a stand...
متن کاملIntensity-modulated radiotherapy increases dose to the brachial plexus compared with conventional radiotherapy for head and neck cancer.
OBJECTIVE The preferential use of intensity-modulated radiotherapy (IMRT) over conventional radiotherapy (CRT) in the treatment of head and neck cancer has raised concerns regarding dose to non-target tissue. The purpose of this study was to compare dose-volume characteristics with the brachial plexus between treatment plans generated by IMRT and CRT using several common treatment scenarios. ...
متن کاملConstraining the brachial plexus does not compromise regional control in oropharyngeal carcinoma
BACKGROUND Accumulating evidence suggests that brachial plexopathy following head and neck cancer radiotherapy may be underreported and that this toxicity is associated with a dose-response. Our purpose was to determine whether the dose to the brachial plexus (BP) can be constrained, without compromising regional control. METHODS The radiation plans of 324 patients with oropharyngeal carcinom...
متن کاملDose Distribution Analysis of Rapid Arc and Intensity Modulated Radiotherapy Plan in Head and Neck Cancer
Introduction: Globally, intensity-modulated radiation therapy (IMRT) is considered as highly precise and accurate method of radiotherapy planning. This technique amplifies spatial dose distribution conformity by modulating the intensity of radiation beams in each sub-volume. Additionally, it can reduces the dose to surrounding critical organs and deliver the planned dose to targets with the nom...
متن کاملUsing overlap volume histogram and IMRT plan data to guide and automate VMAT planning: a head-and-neck case study.
PURPOSE To investigate whether an overlap volume histogram (OVH)-driven planning application using an intensity-modulated radiation therapy (IMRT) database can guide and automate volumetric-modulated arc therapy (VMAT) planning for head-and-neck cancer. METHODS Based on comparable head-and-neck dosimetric results between planner-generated VMAT and IMRT plans, an inhouse developed, OVH-driven ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 10 شماره
صفحات -
تاریخ انتشار 2015