Prevention of lung-to-lung aspiration during emergency thoracic surgery: an experimental study

نویسندگان

  • Jin-Young Hwang
  • Jiseok Baik
  • Sahngun Francis Nahm
  • Dongjin Kim
  • Young-Tae Jeon
  • Jinhee Kim
  • Seongjoo Park
  • Sunghee Han
چکیده

BACKGROUND Lung separation is essential for an emergency thoracic surgery for massive hemoptysis. When using a double lumen tube (DLT), a commonly adopted lung separation device during thoracic surgery, a water-tight seal of endobronchial cuff is crucial to prevent lung-to-lung aspiration of blood. In this study, we investigated the fluid sealing characteristics of the endobronchial cuff of a DLT and examined the effect of gel lubrication on the fluid leakage beyond the endobronchial cuff of DLT. METHODS An artificial tracheobronchial tree was intubated with a DLT. In the first phase of the study, the intra-cuff pressure of endobronchial cuff of DLT was set to 25, 50, or 100 cmH2O (n = 7, each), and the non-dependent bronchus was filled with 5 ml of water. Fluid leakage to the dependent bronchus beyond the endobronchial cuff was collected for 6 h. The time until leakage was first detected and the time until 100% leakage occurred were measured. In the second phase, the endobronchial cuff was coated with either saline (group C, n = 10) or lubricant gel (group GEL, n = 10), and the same parameters were measured. RESULTS In the first phase of the study, the times to first leakage and 100% leakage at an intra-cuff pressure of 25 cmH2O were 21.0 (7.0 - 59.0) sec and 3.0 (2.0 - 4.0) min, respectively. Higher intra-cuff (50 and 100 cmH2O) resulted in longer time for the first leakage and 100% leakage, but the duration was not long enough for clinical purpose. In the second phase, all the DLTs in group C showed 100% fluid leakage during the 6-hour period. In contrast, in group GEL, fluid leakage beyond the endobronchial cuff was detected only in 50% of the DLTs and none of the DLT showed 100% fluid leakage during the study. Among the DLTs which exhibited fluid leakage, the time to first leakage was 252.0 (171.0-305.0) min and the leakage volume at the end of the study period was 0.3〔0.0-1.8〕ml. CONCLUSIONS Endobronchial cuff of DLT cannot prevent fluid leakage beyond the endobronchial cuff, but lubricant gel coating on the endobronchial cuff can effectively reduce the lung-to-lung aspiration.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigation of histopathological and radiological effects of surfactant treatment in an experimental female rat model of lung contusion

Objective(s): Pulmonary contusion (PC) is a clinical entity that often accompanies blunt traumas. We aimed to investigate the radiological and histopathological effects of surfactant treatment in an experimental rat model in which lung contusion was formed by blunt thoracic trauma.Materials and Methods: 50 female Sprague-Dawley rats were...

متن کامل

Determination of the Effects of Digoxin on the Right Ventricular Function in Patients Undergoing Pneumonectomy

Introduction: Pneumonectomy is the standard treatment of lung cancer, even though patients should undergo several evaluations before surgery; deterioration of cardiopulmonary function after pulmonary resection is inevitable. We have evaluated the effects of digoxin on the improvement of right ventricular function and prevention of probable complications after lung resection surgery. Materials a...

متن کامل

Letter of Editor-in-Chief

Dear Colleagues,   As Editor-In-Chief of Journal of Cardio-Thoracic Medicine (JCTM), it is my pleasure to introduce this official quarterly publication of Mashhad University of Medical Sciences, which is an international, peer-reviewed, and English language journal. Our aim is to publish high quality integrating clinical and experimental research in the following fields: Respiratory medici...

متن کامل

Changes in Blood Gases and Hemodynamic Parameters in Patients Undergoing Lung Resection Surgery and Its Clinical Implications

Introduction: Lung resection surgery is a challenge to thoracic surgeons. Outcome of surgery depends on patients’ tolerance to reduced lung volume and hemodynamic alterations. The present study aimed to investigate the changes in blood gases and hemodynamic parameters in patients undergoing lung resection surgery and the associated clinical implications. Materials and methods: This study includ...

متن کامل

Surgical management of cardiac tamponade: Is left anterior minithoracotomy really safe and effective?

Objective: Cardiac tamponade is a life-threatening clinical entity that requires an emergency treatment. Cardiac tamponade can be caused both by benign and malignant diseases. A variety of methods have been described for the treatment of these cases from needle-guided pericardiocentesis, balloon-based techniques to surgical pericardiotomy. The Authors report their experience in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015