Catastrophic failure of an acetabular total hip arthroplasty component mimicking a posterior dislocation
نویسندگان
چکیده
In our case study, we examine a case of catastrophic failure of a total hip arthroplasty acetabular component leading to complete central wear by the ceramic femoral head, requiring revision total hip arthroplasty. Despite subtle clinical findings, initial orthopaedic evaluation and treatment yielded a diagnosis of total hip arthroplasty dislocation. While a much more common phenomenon, the diagnosis led to futile initial attempts at closed reduction. Our index of suspicion must remain high to pick up on subtle, less common diagnoses we will encounter.
منابع مشابه
Catastrophic Failure of the Acetabular Polyethylene Liner in Ceramic-on-Polyethylene Total Hip Arthroplasty
INTRODUCTION Catastrophic polyethylene failure is a rare complication of ceramic-on-polyethylene total hip arthroplasty due to the favorable tribological characteristics of ceramic. Failure of the polyethylene liner can be disastrous, increasing periprosthetic osteolysis, metallosis, and risk of dislocation. Complications associated with ceramic-on-polyethylene articulations have been studied e...
متن کاملReducing the risk of dislocation after total hip arthroplasty: the effect of orientation of the acetabular component.
Malposition of the acetabular component is a risk factor for post-operative dislocation after total hip replacement (THR). We have investigated the influence of the orientation of the acetabular component on the probability of dislocation. Radiological anteversion and abduction of the component of 127 hips which dislocated post-operatively were measured by Einzel-Bild-Röentgen-Analysis and comp...
متن کاملPosterior Hip Fracture -Dislocation Associated with Ipsilateral Intertrochantric Fracture; a Rare Case Report
Hip dislocation occurs when the femur does not break and the force is transmitted towards the hip joint leading to a posterior dislocation of the femoral head with or without posterior acetabular fracture. We present the case of a 26 year old patient involved in motor vehicle accident. Clinical and imaging (radiography, CT) examination revealed an intertrochanteric fracture associated with ipsi...
متن کاملRedefining the Acetabular Component Safe Zone for Posterior Approach Total Hip Arthroplasty.
BACKGROUND Acetabular component orientation influences joint stability in total hip arthroplasty (THA). The purpose of this study was to evaluate the effect of cup orientation and other variables on hip dislocation risk and to define a posterior approach specific safe zone. METHODS A cohort of 1289 posterior approach primary THA cases was prospectively followed and component position measured...
متن کاملThe Result of Revision Total Hip Arthroplasty in Patients with Metallosis Following a Catastrophic Failure of a Polyethylene Liner
BACKGROUND Wear cannot be completely prevented after total hip arthroplasty. If severe polyethylene (PE) liner wear develops, the so-called catastrophic failure occurs and metallosis develops. We postulated that longevity of the new implant may be affected after revision surgery for metallosis following a catastrophic failure of a PE liner due to the substantial amount of PE wear particles and ...
متن کامل