Bispectral index monitoring prevent awareness during total intravenous anesthesia: a prospective, randomized, double-blinded, multi-center controlled trial.

نویسندگان

  • Chen Zhang
  • Liang Xu
  • Ya-Qun Ma
  • Yan-Xia Sun
  • Yan-Hong Li
  • Liang Zhang
  • Chun-Sheng Feng
  • Bing Luo
  • Zhen-Long Zhao
  • Jian-Rong Guo
  • Yao-Jun Jin
  • Gang Wu
  • Wei Yuan
  • Zhi-Guo Yuan
  • Yun Yue
چکیده

BACKGROUND Awareness is a serious complication of general anesthesia. In China, the incidence of intraoperative awareness was 1% in patients undergoing total intravenous anesthesia (TIVA). In this study, we compared the incidence of awareness between Bispectral index (BIS)-guided and routine TIVA protocol and evaluated the effect of BIS on preventing awareness. METHODS A prospective, randomized, double-blinded, multicenter controlled trial was performed. Patients (≥ 18 years of age) undergoing TIVA were randomly divided into BIS-guided group (Group A, BIS was monitored and recommended to maintain between 40 - 60) and control group (Group B, BIS was monitored but the screen was covered). The intraoperative BIS values were downloaded and the BIS trends of confirmed awareness cases were analyzed to determine whether light anesthesia existed. RESULTS Of the total 5228 patients, 2919 patients were assigned to Group A and 2309 to Group B. Four cases of confirmed awareness (0.14%) were reported in the BIS-guided group and 15 (0.65%) in the control group (P = 0.002, OR = 0.21, 95% confidence intervals: 0.07 - 0.63). The incidence of possible awareness (0.14% vs. 0.26%, P = 0.485) and dreaming (3.1% vs. 3.1%, P = 0.986) was comparable between BIS-guided group and the control group. Among the 19 confirmed awareness cases, intraoperative BIS trends of six cases were downloaded and identified. Five of them showed signs of light anesthesia as BIS > 60 and lasted 19 - 106 minutes, whereas one case had a stable BIS trend and the values were within 60 during the operation. Another five awareness cases were reviewed for anesthesia procedures, of which improper light anesthesia were confirmed. CONCLUSIONS BIS-guided TIVA (BIS was recommended to maintain between 40 - 60) decreased the risk of awareness compared with routine TIVA. The main reason for awareness was light anesthesia.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Protocol for the "Michigan Awareness Control Study": A prospective, randomized, controlled trial comparing electronic alerts based on bispectral index monitoring or minimum alveolar concentration for the prevention of intraoperative awareness

BACKGROUND The incidence of intraoperative awareness with explicit recall is 1-2/1000 cases in the United States. The Bispectral Index monitor is an electroencephalographic method of assessing anesthetic depth that has been shown in one prospective study to reduce the incidence of awareness in the high-risk population. In the B-Aware trial, the number needed to treat in order to prevent one cas...

متن کامل

Bispectral index monitoring to prevent awareness during anaesthesia: the B-Aware randomised controlled trial.

BACKGROUND Awareness is an uncommon complication of anaesthesia, affecting 0.1-0.2% of all surgical patients. Bispectral index (BIS) monitoring measures the depth of anaesthesia and facilitates anaesthetic titration. In this trial we determined whether BIS-guided anaesthesia reduced the incidence of awareness during surgery in adults. METHODS We did a prospective, randomised, double-blind, mu...

متن کامل

Protocol for the BAG-RECALL clinical trial: a prospective, multi-center, randomized, controlled trial to determine whether a bispectral index-guided protocol is superior to an anesthesia gas-guided protocol in reducing intraoperative awareness with explicit recall in high risk surgical patients

BACKGROUND Awareness with explicit recall of intra-operative events is a rare and distressing complication that may lead to severe psychological symptoms. Candidate depth of anesthesia monitors have been developed, partly with the aim of preventing this complication. Despite conflicting results from clinical trials and the lack of incisive validation, such monitors have enjoyed widespread clini...

متن کامل

Do we need bispectral index monitoring during total intravenous anesthesia for lumbar discectomies?

The aim of this study was to investigate the effect of bispectral index (BIS) monitoring on hemodynamic parameters, drug consumption and awareness during total intravenous anesthesia (TIVA) with remifentanil and propofol in lumbar discectomies. After institutional ethical committee approval, ASAI-II 56 patients were divided as control and BIS groups. Anesthesia was induced by bolus remifentanil...

متن کامل

Novel Incorportation Of Biomedical Engineering Algorithms (bispectral Index Guided Or Anesthetic Concentration Guided) In Real-Time Decision Support To Prevent Intraoperative Awareness Using An Electronic Anesthesia Information Mananagement System

NOVEL INCORPORATION OF BIOMEDICAL ENGINEERINGALGORITHMS (BISPECTRAL INDEX GUIDED OR ANESTHETICCONCENTRATION GUIDED) IN REAL-TIME DECISION SUPPORT TOPREVENT INTRAOPERATIVE AWARENESS USING AN ELECTRONICANESTHESIA INFORMATION MANAGEMENT SYSTEMbyAMY MELANIE SHANKSMay 2015 Advisors: Drs. John M. Cavanaugh and George A. Mashour Major: Biomedical Engineering Degree: Doc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chinese medical journal

دوره 124 22  شماره 

صفحات  -

تاریخ انتشار 2011