Significantly improved lifetime of Microchannel Plate PMTs∗
نویسندگان
چکیده
The main particle identification devices of the PANDA experiment will be two DIRCs placed around (barrel) and downstream (disc) of the target. The preferred photon sensor option are microchannel plate (MCP) PMTs because they can be operated inside the 2 Tesla magnetic field of the solenoid. Furthermore, these multi-anode sensors are rather compact and show a superior time resolution which is typically <50 ps. Until recently the major drawbacks of MCP-PMTs were serious shortcomings with their rate capability and in particular with aging effects. The main cause of aging are restgas ions in the tube being accelerated towards the photo cathode (PC), whose surface gets damaged by their impact and the quantum efficiency (QE) suffers. Although the rate capability issue was resolved already a few years ago, the aging remained a serious problem [1, 2]. In the latest generation of MCP-PMTs important counter measures were taken to seriously tackle the aging problem. These include a higher vacuum inside the tube and electron scrubbing of the MCP surfaces (PHOTONIS, BINP), an Al2O3 protection layer between the 2 MCPs (Hamamatsu R10754X), an ALD coating of the whole MCP capillaries to prevent outgassing of the glass substrate (PHOTONIS XP85112), and even a modified photo cathode (BINP). For further details see Ref. [3]. At the design luminosity of PANDA the anticipated photon rates at the DIRC focal planes range from a few hundred kHz for the barrel DIRC to several MHz at the disc DIRC. Integrated over the envisaged 10 years operation period of the PANDA experiment these rates accumulate to anode charges of ≈5 C/cm for the barrel DIRC and even more for the disc DIRC. Since about 18 months we are simultaneously and permanently illuminating the most recent MCP-PMTs to study their aging. The single photon rate at the PCs is chosen to be comparable to that expected in the PANDA environment. The accumulated anode charge is determined by a permanent monitoring of the pulse heights. Every few days a wavelength scan of the QE is done for all illuminated MCP-PMTs. In addition, every few months a QE scan as a function of the PC surface is performed to identify critical regions where the QE may start to drop. Currently, >4 C/cm of integrated anode charge are accumulated. In Fig. 1 the behaviour of the quantum efficiency at a wavelength of 400 nm is compared for several MCP-PMTs. While the QE of the older models (open dots) dropped to 5% after typically <300 mC/cm the results for the most recent models (solid dots) is very different. In particular, the ALD coated PHOTONIS XP85112 shows
منابع مشابه
Measurements of Cherenkov Photons with Silicon Photomultipliers
A novel photon detector, the Silicon Photomultiplier (SiPM), has been tested in proximity focusing Ring Imaging Cherenkov (RICH) counters that were exposed to cosmic-ray particles in Ljubljana, and a 2 GeV electron beam at the KEK research facility. This type of RICH detector is a candidate for the particle identification detector upgrade of the BELLE detector at the KEK B-factory, for which th...
متن کاملBeam test of a Time-of-Flight detector prototype
We report on results of a Time-of-Flight, TOF, counter prototype in beam tests at SLAC and Fermilab. Using two identical 64-pixel Photonis Microchannel Plate Photomultipliers, MCP-PMTs, to provide start and stop signals, each having a 1 cm-long quartz Cherenkov radiator, we have achieved a timing resolution of σSingle_detector ~14 ps. To be published in Nucl. Instr.& Methods ——— • Manuscript re...
متن کاملRecent Developments in Ultra-High Speed and Large Area Photomultiplier Tubes
Photek has been working with AWE to provide photomultiplier (PMT) solutions for fusion diagnostics. By using microchannel plates (MCP) as the gain medium, the time response of the PMTs can be as fast as 100 ps FWHM. We will present data showing developments in the accurate measurement of the true impulse response of the fastest detectors. We will also show improvements in the pulse uniformity a...
متن کاملCross Strip Anode Imaging Readouts for Microchannel Plate Detectors
We have developed a novel microchannel plate readout scheme, the cross strip anode. The cross strip anode has a coarse (0.5mm) multilayer metal and ceramic cross strip pattern that encodes event positions by direct sensing of the charge on each strip and subsequent determination of the charge cloud centroid for each event. Event position encoding is accomplished with chip level preamplifiers on...
متن کاملDetermination of the timing properties of the pulsed positron lifetime beam by the application of an electron gun and a fast microchannel plate
We show that the timing properties of a pulsed low-energy positron lifetime beam can be conveniently tested by an electron beam. We apply this method to study time resolution of the beam and electron scattering in a flat and a ’sawtooth’ shaped choppers. The results show that (i) time resolution of 160 ps is obtained, (ii) the scattering of the electrons and the secondary electron yield of the ...