Bacteremia in hemodialysis patients
نویسندگان
چکیده
Infection is a common complication and is the second leading cause of death in hemodialysis patients. The risk of bacteremia in hemodialysis patients is 26-fold higher than in the general population, and 1/2-3/4 of the causative organisms of bacteremia in hemodialysis patients are Gram-positive bacteria. The ratio of resistant bacteria in hemodialysis patients compared to the general population is unclear. Several reports have indicated that hemodialysis patients have a higher risk of methicillin-resistant Staphylococcus aureus infection. The most common site of infection causing bacteremia is internal prostheses; the use of a hemodialysis catheter is the most important risk factor for bacteremia. Although antibiotic lock of hemodialysis catheters and topical antibiotic ointment can reduce catheter-related blood stream infection (CRBSI), their use should be limited to necessary cases because of the emergence of resistant organisms. Systemic antibiotic administration and catheter removal is recommended for treating CRBSI, although a study indicated the advantages of antibiotic lock and guidewire exchange of catheters over systemic antibiotic therapy. An infection control bundle recommended by the Center for Disease Control and Prevention succeeded in reducing bacteremia in hemodialysis patients with either a catheter or arteriovenous fistula. Appropriate infection control can reduce bacteremia in hemodialysis patients.
منابع مشابه
بررسی سطح اندوتوکسین خون بیماران همودیالیزی و مقایسه آن با کشت خون
Introduction: Presently, bacteremia is the principal cause of morbidity in patients undergoing hemodialysis. Gram-negative bacteria account for approximately 50 percent of documented infections. Endotoxins released during lysis of gram negative bacteremia result in inflammatory and defense response by the body and if not treated promptly result in septic shock and ultimately death of the patie...
متن کاملKlebsiella pneumoniae bacteremia associated with a Tesio hemodialysis catheter.
Klebsiella pneumoniae bacteremia associated with a Tesio hemodialysis catheter To the Editor: Catheter-associated bacteremia is a serious complication of temporary hemodialysis vascular access. Bacteremia is the second leading cause of death in hemodialysis patients. Infectious episodes are also the leading cause for untimely catheter removal and for morbidity in dialysis patients. In a study o...
متن کاملIs Taurolidine-citrate an effective and cost-effective hemodialysis cathe-ter lock solution? A systematic review and cost- effectiveness analysis
Background: Prevention of catheter-related infection is of prime importance,. However, because of the risks caused by the leakage of circulating antibiotics and development of resistance to antibiotics, they are replaced by lock solutions. The aim of this study was to evaluate the efficacy and cost- effectiveness of taurolidine-citrate as a hemodialysis catheter lock solution compared to other ...
متن کاملMethicillin-resistant Staphylococcus aureus bacteremia in hemodialysis and nondialysis patients.
BACKGROUND/PURPOSE Increased mortality has been reported in patients treated with vancomycin for methicillin-resistant Staphylococcus aureus (MRSA) bacteremia with high minimum inhibitory concentration (MIC) values within the susceptibility range. However, this finding has not been verified in hemodialysis patients, who have much higher invasive MRSA infection rates than nondialysis patients. W...
متن کاملCatheter-related bacteremia caused by Agrobacterium radiobacter in a hemodialysis patient.
Agrobacterium radiobacter, a Gram-negative bacillus, is recognized as an emerging opportunistic human pathogen that has a propensity to cause infections in patients with indwelling foreign devices. Here, we describe the first reported case of catheter-related bacteremia caused by A. radiobacter in a hemodialysis patient with a long-term tunneled-cuffed hemodialysis catheter. This case shows tha...
متن کامل