TASER electronic control devices and cardiac arrests: coincidental or causal?

نویسندگان

  • Mark W Kroll
  • Dhanunjaya R Lakkireddy
  • James R Stone
  • Richard M Luceri
چکیده

TASER Electronic Control Devices and Cardiac Arrests: Coincidental or Causal? Print ISSN: 0009-7322. Online ISSN: 1524-4539 Copyright © 2014 American Heart Association, Inc. All rights reserved. is published by the American Heart Association, 7272 Greenville Avenue, Dallas, TX 75231 Circulation doi: 10.1161/CIRCULATIONAHA.113.004401 2014;129:93-100 Circulation. http://circ.ahajournals.org/content/129/1/93 World Wide Web at: The online version of this article, along with updated information and services, is located on the http://circ.ahajournals.org/content/suppl/2014/01/07/129.1.93.DC1.html Data Supplement (unedited) at:

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Letter by Vilke et al regarding article, "sudden cardiac arrest and death following application of shocks from a TASER electronic control device".

BACKGROUND The safety of electronic control devices (ECDs) has been questioned. The goal of this study was to analyze in detail cases of loss of consciousness associated with ECD deployment. METHODS AND RESULTS Eight cases of TASER X26 ECD-induced loss of consciousness were studied. In each instance, when available, police, medical, and emergency response records, ECD dataport interrogation, ...

متن کامل

Sudden Cardiac Arrest and Death Associated with Application of Shocks from a TASER Electronic Control Device

Background—The safety of electronic control devices (ECDs) has been questioned. The goal of this study was to analyze in detail cases of loss of consciousness associated with ECD deployment. Methods and Results—Eight cases of TASER X26 ECD–induced loss of consciousness were studied. In each instance, when available, police, medical, and emergency response records, ECD dataport interrogation, au...

متن کامل

Sudden Cardiac Arrest and Death Following Application of Shocks From a TASER Electronic Control Device

Background—The safety of electronic control devices (ECDs) has been questioned. The goal of this study was to analyze in detail cases of loss of consciousness associated with ECD deployment. Methods and Results—Eight cases of TASER X26 ECD–induced loss of consciousness were studied. In each instance, when available, police, medical, and emergency response records, ECD dataport interrogation, au...

متن کامل

Arrhythmia/Electrophysiology Sudden Cardiac Arrest and Death Following Application of Shocks From a TASER Electronic Control Device

Background—The safety of electronic control devices (ECDs) has been questioned. The goal of this study was to analyze in detail cases of loss of consciousness associated with ECD deployment. Methods and Results—Eight cases of TASER X26 ECD–induced loss of consciousness were studied. In each instance, when available, police, medical, and emergency response records, ECD dataport interrogation, au...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 129 1  شماره 

صفحات  -

تاریخ انتشار 2014