Respiratory bellows revisited for motion compensation: preliminary experience for cardiovascular MR.
نویسندگان
چکیده
For many cardiac MR applications, respiratory bellows gating is attractive because it is widely available and not disruptive to or dependent on imaging. However, its use is uncommon in cardiac MR, because its accuracy has not been fully studied. Here, in 10 healthy subjects, the bellows and respiratory navigator (NAV) with the displacement of the diaphragm and heart were simultaneously monitored, during single-shot imaging. Furthermore, bellows-gated and NAV-gated coronary MRI were compared using a retrospective reconstruction at identical efficiency. There was a strong linear relationship for both the NAV and the abdominal bellows with the diaphragm (R = 0.90 ± 0.05 bellows, R = 0.98 ± 0.01 NAV, P < 0.001) and the heart (R = 0.89 ± 0.06 bellows, R = 0.96 ± 0.02 NAV, P = 0.004); thoracic bellows correlated less strongly. The image quality of bellows-gated coronary MRI was similar to NAV-gated and superior to no-gating (P < 0.01). In conclusion, bellows provides a respiratory monitor which is highly correlated with the NAV and suitable for respiratory compensation in selected cardiac MR applications.
منابع مشابه
Retrospective bellows-based reconstruction for cardiac MRI: preliminary experience
Introduction: The two most common methods for respiratory compensation of cardiac MR (CMR) studies are breath-holding and navigator-gating. Respiratory bellows is a long-established, readily available method, but has been rarely used in cardiac imaging, with some exceptions [1,2,3]. This study compares the performance of respiratory chest wall and abdomen bellows to navigator-gating (NAV), and ...
متن کامل3D respiratory resolved phase contrast imaging of the aorta
Background Respiratory motion compensation is essential for reproducible and robust cardiovascular MRI. Traditionally, breathholds or prospective gating by bellows or navigator signals limit data acquisition to the quiescent phase of respiration [1]. These approaches do not capture any variations of blood flow over the respiratory cycle, yet respiration has been shown to significantly affect fl...
متن کاملCorrecting for respiratory motion in liver PET/MRI: preliminary evaluation of the utility of bellows and navigated hepatobiliary phase imaging
BACKGROUND The purpose of this study was to evaluate the utility of bellows-based respiratory compensation and navigated hepatobiliary phase imaging to correct for respiratory motion in the setting of dedicated liver PET/MRI. METHODS Institutional review board approval and informed consent were obtained. Six patients with metastatic neuroendocrine tumor were imaged using Ga-68 DOTA-TOC PET/MR...
متن کاملCardiac and respiratory motion compensated reconstruction driven only by 1D navigators
INTRODUCTION Cardiac MRI requires compensation of respiratory and cardiac motion, which is usually performed by gating using an ECG and breathing signal. Recently, a motion compensated reconstruction of arbitrary physiological motion was proposed [1], that is based on a generalized reconstruction by inversion of coupled systems (GRICS) and uses a motion model and a reduced number of 1D input si...
متن کاملMotion correction strategies for integrated PET/MR.
UNLABELLED Integrated whole-body PET/MR facilitates the implementation of a broad variety of respiratory motion correction strategies, taking advantage of the strengths of both modalities. The goal of this study was the quantitative evaluation with clinical data of different MR- and PET-data-based motion correction strategies for integrated PET/MR. METHODS The PET and MR data of 20 patients w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Magnetic resonance in medicine
دوره 65 4 شماره
صفحات -
تاریخ انتشار 2011