Evaluation of floating and sticking extended release delivery systems: an unconventional dissolution test.
نویسندگان
چکیده
The extent to which hydrophilic matrix tablets with a propensity to stick to the dissolution apparatus and/or float are susceptible to variations in hydrodynamic conditions during dissolution testing was investigated. Furthermore the usefulness of simple alternatives to the current compendial tests is examined. Swellable hydrocolloid (guar) matrix tablets containing verapamil HCl were evaluated using USP dissolution apparatus I and II. Two additional configurations where an additional single ring and mesh device or a double mesh device was located below the paddle in the dissolution vessel were also evaluated. Tablets were placed on top of the single mesh device or in the compartment formed by the two mesh surfaces of the double mesh device. In all cases near linear (n>/=0.82) release profiles were observed. When using apparatus I it was observed that the highly swellable tablets were fully constricted by the basket within 5-7 h. This prevented further independent movement and unimpeded swelling and coincided with a departure from linear release and increased variability (S.D.</=9.5%). Under standard apparatus II conditions two out of three tablets adhered to the bottom of the dissolution vessel for the duration of the experiment. Consequently their release profiles differed markedly from those obtained under apparatus I conditions (similarity factor, f(2)=30.5) with the release rate being approximately half of that obtained under apparatus I conditions. Adhesion to the dissolution vessel was also observed when paddle speed was doubled to 100 rpm, thus again resulting in large variability (S.D.</=34%). Whilst the averaged single and double mesh configuration profiles were similar to the apparatus I profile (f(2)=57.36 and 61.38, respectively), large variability (S.D.</=11%) occurred with the single mesh configuration due to floating and random adhesion of tablets to the paddle or sampling tubes. Almost superimposable profiles were obtained for the individual tablets (S.D.<3%) when the tablets were located in the compartment formed by the double mesh device. Use of a double mesh device may therefore provide an alternative to current compendial dissolution methods when the reliable determination of the true release kinetics of floating and sticking delivery systems is desired.
منابع مشابه
Controlled-Release Low Density Effervescent Floating Matrix Tablets of Risperidone: Development, Optimization, in vitro-in vivo Evaluation in Healthy Human Volunteers and Determination of Dissolution Equivalency
The main objective of the present study was to formulate gastroretentive effervescent sustained release drug delivery systems of risperidone floating tablets with the help of Methocel® K15, Ethocel® standard 7FP premium, Eudragit ® RS100 sustained release polymers to improve its safety profile, bioavailability and patient compliance. Risperidone floating tablets were formulated by wet granulati...
متن کاملDesign and Evaluation of a Novel Bio-Mimicking In Vitro Dissolution Test Apparatus for Floating Drug Delivery Systems
The aim of the present study was to design a new biorelevant dissolution test apparatus for evaluating floating drug delivery systems. The gastric fluid secretion rate, volume of gastric fluid present in the stomach, and gastric emptying from the pylorus opening were taken into consideration. The material of construction was borosilicate glass. In vitro dissolution testing of pharmaceutical dos...
متن کاملEvaluation and comparison of dissolution data derived from different modified release dosage forms: an alternative method.
Dissolution testing is an essential requirement for the development, establishment of in vitro dissolution and in vivo performance (IVIVR), registration and quality control of solid oral dosage forms. The objective of the present study was to investigate the effect of delivery system positioning in accordance with the USP 23-recommended dissolution methods and the proposed modification on drug ...
متن کاملSodium Alginate/Starch Blends Loaded with Ciprofloxacin Hydrochloride as a Floating Drug Delivery System - In Vitro Evaluation
In the present study, Floating Drug Delivery Beads (FDDS) were prepared with sodium alginate/ starch blend as a matrix, sodium hydrogen carbonate as a pore forming agent, methyl cellulose as a binder and barium chloride solution as a hardening agent. In order to prepare the beads with different porosity and morphology the ratio between pore forming agent to polymer blend and ratio of the co...
متن کاملPreparation of Alprazolam Extended- Release Tablets and In vitro Characterization
Abstract The main aim of this study was to prepare and evaluate the extended - release system of an anxiolytic substance. Alprazolam is a short-acting benzodiazepine with general properties similar to those of diazepam. Our studies focused on the development of extended drug delivery system based on Hydroxy Propyl Methyl Cellulose (HPMC 4000cps) as retard agent and polyvinylpyrrolidone (PVP k30...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of controlled release : official journal of the Controlled Release Society
دوره 67 1 شماره
صفحات -
تاریخ انتشار 2000