Evaluation of load-deflection properties of fiber-reinforced composites and its comparison with stainless steel wires
نویسندگان
چکیده
BACKGROUND The aim of this study was to evaluate the response of common sized fiber-reinforced composites (FRCs) to different deflections due to bending forces and comparing it with stainless steel (SS) wires. MATERIALS AND METHODS In this experimental study, two FRC groups with 0.75 mm and 1.2 mm diameters (Everstick Ortho, Stick Tech, Finland) and three SS groups with 0.016 × 0.022 inch, 0.0215 × 0.028 inch and 0.7 mm diameters (3M Uniteck, Monrovia, California, USA) were tested. Each group contained 10 samples that were tested according to a three point bending test. Each group was tested at deflections of 0.5, 1 and 1.5 mm and the data was analyzed using the repeated measure ANOVA by SPSS software (Statistical Package for the Social Sciences, IBM SPSS, Inc. in Chicago, Illinois, USA). P < 0.05 was considered as significant. RESULTS The highest recorded load belonged to the 1.2 mm FRC and after that 0.7 mm SS wire, 0.75 mm FRC, 0.0215 × 0.028 inch SS wire and finally 0.016 × 0.022 inch SS wire. The 0.7 mm SS wire and 0.75 mm FRC were compared as retainers and the results showed the 0.7 mm SS wire showed significantly higher load compared with 0.75 mm FRC (P < 0.05). The 1.2 mm FRC had significantly higher load compared to 0.0215 × 0.028 inch and 0.016 × 0.022 inch SS wires (P < 0.05). CONCLUSION The results showed that the 1.2 mm FRC group had significantly higher load compared to SS wires and other FRC groups under the 0.5, 1 and 1.5 mm deflections. Therefore, it can be suggested that FRC can be used as an esthetic replacement for SS wires for active and passive purposes in orthodontics.
منابع مشابه
Bending Properties of Fiber-Reinforced Composites Retainers Bonded with Spot-Composite Coverage
Orthodontic and periodontal splints are prepared with round or flat metallic wires. As these devices cannot be used in patients with allergy to metals or with aesthetic demands, fiber-reinforced composite (FRC) retainers have been introduced. Stiffness of FRC materials could reduce physiologic tooth movement. In order to lower rigidity of conventional FRC retainers, a modified construction tech...
متن کاملSignificance of stainless steel wire reinforcement on the mechanical properties of GFRP composites
Investigations on flexural and tensile properties of GFRP laminates influenced by stainless steel wire reinforcement were carried out as a novel approach. Plain GFRP laminates and GFRP laminates reinforced with stainless steel wires at different depth with various pitch distances were fabricated by hand layup method. The composite specimens reinforced with steel wires were exposed to low freque...
متن کاملComparison between fiber-reinforced polymers and stainless steel orthodontic retainers
Objective The aim of this study was to examine the properties of fiber-reinforced composite and stainless steel twisted retainers for orthodontic retention. Methods Three different span lengths (5.0, 8.0, and 14.0 mm) of fiber-reinforced composite were investigated. The three fiber-reinforced composite retainer groups were subdivided according to the storage condition (dry and wet), resulting...
متن کاملMechanical Behavior of Stainless Steel Fiber-Reinforced Composites Exposed to Accelerated Corrosion
Recent advancements in metal fibers have introduced a promising new type of stainless steel fiber with high stiffness, high failure strain, and a thickness < 100 μm (<0.00394 in.) that can be utilized in a steel fiber-reinforced polymer. However, stainless steel is known to be susceptible to pitting corrosion. The main goal of this study is to compare the impact of corrosion on the mechanical p...
متن کاملMixed Mode Fracture in Reinforced Concrete with Low Volume Fraction of Steel Fibers
An investigation into the mixed mode fracture of steel fiber reinforced concrete (SFRC)beams with one percent volume fraction of steel fiber is presented. A series of notched beams withdifferent notch depths and locations are tested under three-point bending. The test results for apparentfracture toughness, crack trajectories, and fracture energy are presented. The crack paths for SFRCand plain...
متن کامل