Cold Sterilization of Cardiac Catheterization Equipment with Ethylene Oxide Gas.

نویسندگان

  • A M SCHMIDT
  • P D HOEPRICH
چکیده

OCCASIONAL infections in sites of venous cutdowns and an episode of fever in a patient following cardiac catheterization caused us to review the procedures used in this laboratory for preparation of catheterization equipment. Materials not susceptible to damage by wet heat (surgical instruments, syringes and needles, drapes) are sterilized in a steam autoclave. Polyethylene catheters, cuvette oximeters,* Statham P23Db strain gages, and other fragile electronic or plastic apparatus, since they may be destroyed by autoclave sterilization, have been boiled in water or soaked with solutions containing variously alcohol, quaternary ammonium compounds, heavy metals, or acids. The standard Cournand cardiac catheter may be boiled or sterilized in an autoclave, but its useful life is shortened by such treatment. Furthermore, since procedures such as boiling and soaking in "antiseptic" solutions are ineffective against a variety of microorganisms, there is some basis for doubt that actual sterilization is thereby accomplished. In order to evaluate the effectiveness of current methods of sterilizing fragile equipment, we obtained a series of cultures from cardiac catheterization equipment prepared according to the usual regimen. Bacterial growth was demonstrated. Cold sterilization with ethylene oxide gas was then introduced; subsequent cultures have indicated that all equipment was then sterile. These results and a brief description of the simple, inexpensive, and convenient

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reaction of the sterilant, ethylene oxide, on plastics.

Ethylene oxide (ETO) in the form, "Cryoxcide,"' is used to sterilize surfaces and objects that cannot be treated with heat or corrosive chemicals. Cryoxcide is a gaseous formulation consisting of 11 per cent of ethylene oxide, 44.5 per cent of trichloromonofluoromethane (Freon 11), and 44.5 per cent of dichlorodifluoromethane (Freon 12). Cryoxcide is used at this laboratory to sterilize sensiti...

متن کامل

The Sterility and Sterilization of Lung Ventilators.

Intermittent positive pressure breathing machines are in use for the treatment of many respiratory and cardiac conditions, but there is no agreement regarding the risk of cross infection and the necessity of sterilizing part, or all, of this equipment. Until recently, complete sterilization has been difficult to effect, and so reliance has been placed on boiling or chemical disinfection of the ...

متن کامل

Detection of endotoxin on sterile catheters used for cardiac catheterization.

Pyrogen reactions during cardiac catheterization are an alarming complication that frightens patients and baffles many physicans. This report describes a simple, reproducible, precise technique for the measurement of endotoxin-like activity on the inner and outer surfaces of catheters intended for intravascular insertion. This technique is useful in documenting the cause of patient reactions. Q...

متن کامل

A Case Study of an Ethylene Oxide Explosion in a Sterilization Facility

Ethylene oxide is widely used as a sterilizing agent for medical and food applications and products. However, due to its broad range of flammability (2.6 % to 100 %) in air, this gas presents a particularly serious explosion hazard, which is compounded by extremely stringent and ever increasing requirements for pollution control equipment. Many emission control devices contain potential ignitio...

متن کامل

Sorption processes in gas sterilization in the medical sector.

Sorption of ethylene oxide during and after gaseous sterilization is influenced by numerous factors. It was found that ethylene oxide desorption not only depends on material to be fumigated but also to a considerable degree on the wrapping material. Although polyethylene, polyamide (nylon), polytetrafluoroethylene (Teflon), silicone, aluminum, and glass beads contained no quantities of ethylene...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 29  شماره 

صفحات  -

تاریخ انتشار 1964