Motion correction for myocardial T1 mapping using image registration with synthetic image estimation.

نویسندگان

  • Hui Xue
  • Saurabh Shah
  • Andreas Greiser
  • Christoph Guetter
  • Arne Littmann
  • Marie-Pierre Jolly
  • Andrew E Arai
  • Sven Zuehlsdorff
  • Jens Guehring
  • Peter Kellman
چکیده

Quantification of myocardial T1 relaxation has potential value in the diagnosis of both ischemic and nonischemic cardiomyopathies. Image acquisition using the modified Look-Locker inversion recovery technique is clinically feasible for T1 mapping. However, respiratory motion limits its applicability and degrades the accuracy of T1 estimation. The robust registration of acquired inversion recovery images is particularly challenging due to the large changes in image contrast, especially for those images acquired near the signal null point of the inversion recovery and other inversion times for which there is little tissue contrast. In this article, we propose a novel motion correction algorithm. This approach is based on estimating synthetic images presenting contrast changes similar to the acquired images. The estimation of synthetic images is formulated as a variational energy minimization problem. Validation on a consecutive patient data cohort shows that this strategy can perform robust nonrigid registration to align inversion recovery images experiencing significant motion and lead to suppression of motion induced artifacts in the T1 map.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improved motion correction using image registration based on variational synthetic image estimation: application to inline t1 mapping of myocardium

Introduction Myocardial T1 mapping has potential to quantify structural and pathological changes without use of contrast agent. Recently Modified Look-Locker Inversion Recovery (MOLLI) sequence has proven effective on cardiac T1 mapping [1]. Its clinical applicability is still limited by myocardial motion between frames mainly due to beat to beat variations and respiration. This undesired motio...

متن کامل

Motion correction using hierarchical local affine registration improves image quality and myocardial scar characterisation from T1 maps acquired with MOLLI

Background T1 mapping enables true quantitative assessment of myocardial tissue, separating scars and healthy myocardium. The modified Look-Locker inversion recovery (MOLLI) sequence acquires eleven images over the duration of a minimum of fifteen heart beats to obtain the final T1 map, which is susceptible to undesired respiratory motion due to a relatively long breath-hold. We aimed to implem...

متن کامل

High-resolution modified look-locker inversion recovery (HR-MOLLI) for RV extracellular volume fraction at 3T and 1.5T: A feasibility study

Background Cardiac MR (CMR) is the reference standard for assessing macroscopic myocardial scar. Determination of the extracellular volume fraction (ECV) by T1 estimation using the modified Look-Locker inversion recovery (MOLLI) correction enables quantitation of diffuse fibrosis. The purpose of this study is to evaluate the feasibility and reproducibility of an optimized high-resolution MOLLI ...

متن کامل

Myocardial T1 and T2 mappings with automatic motion correction at 3 Tesla MR: comparison of T1 and T2 measurements by breathhold, free-breathing and cardiac cycle

Methods Myocardial T1 and T2 mapping at 3 Tesla MR was obtained from 24 healthy volunteers (16 males and 8 females, mean age, 31±4 years). Shortened modified looklocker inversion recovery was used for T1 mapping and T2-prepared single-shot steady-state free precession was utilized for T2 mapping. Automatic motion correction was done by an elastic registration algorithm based on estimating motio...

متن کامل

اصلاح حرکت در تصویربرداری اسپکت میوکارد با استفاده از مدل‌سازی منحنی چند جمله ای

Background and purpose: Patient motion during myocardial perfusion SPECT can produce artifacts in reconstructed images which might affect clinical diagnosis. This paper attempts to present a new approach for the detection and correction of cardiac motion utilizing the data obtained during the imaging process. Materials and methods: Our method quantifies motion through polynomial curves modelin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 67 6  شماره 

صفحات  -

تاریخ انتشار 2012