Sensitive and specific quantification of sirolimus (rapamycin) and its metabolites in blood of kidney graft recipients by HPLC/electrospray-mass spectrometry.
نویسندگان
چکیده
Sirolimus (rapamycin) has a macrolide structure and is under clinical investigation as an immunosuppressant after organ transplantation. An HPLC/mass spectrometry assay to quantify sirolimus in blood was developed. 28-O-Acetyl sirolimus was used as internal standard. Blood samples were extracted with C18 columns. The extracts were injected into an HPLC system and isocratically eluted with methanol/1% formic acid (90/10 by vol) from a 150 X 4 mm C18 analytical column. The HPLC system was connected to a triple-stage quadrupole mass spectrometer with an electrospray interface and positive ions were detected. The limit of quantification in 1 mL of blood was 0.25 microgram/L and the calibration curve in blood was linear up to 250 microgram/L. The recovery from blood was 88 +/- 26% and interassay variation at 1 microgram/L was 19% and at 15 microgram/L 9.3%. Hydroxy, dihydroxy, demethyl, and didemethyl sirolimus as well as sirolimus were detected in blood of kidney graft patients.
منابع مشابه
Liquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization
A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...
متن کاملLiquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization
A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...
متن کاملAutomated simultaneous quantification of the immunosuppressants 40-O-(2-hydroxyethyl) rapamycin and cyclosporine in blood with electrospray-mass spectrometric detection.
A new analytical method to quantify 40-O-(2-hydroxyethyl)rapamycin (SDZ RAD) and cyclosporine (Cs) simultaneously in blood is presented. The combination of an on-line solid-phase extraction step with an HPLC system coupled to an electrospray mass spectrometer gave excellent specificity, sensitivity, and reproducibility. Aliquots of deproteinized blood samples were injected into the HPLC system ...
متن کاملQuantification of sirolimus by liquid chromatography-tandem mass spectrometry using on-line solid-phase extraction.
Quantification of the new immunosuppressant sirolimus (syn. rapamycin; Rapamune) in whole blood by chromatography is essential for its clinical use since no immunoassay is available although monitoring is mandatory. Here we report on a rapid and convenient liquid chromatography (LC-tandem mass spectrometry method and describe our practical experience with its routine use. Whole blood samples we...
متن کاملA Reversed Phase High Performance Liquid Chromatographic Method for Determination of Rapamycin
Easily degradating and various isomeric forms of rapamycin (Sirolimus) face the determination of this compound to many challenges. In this study, we developed and validated the isocratic reversed phase high performance liquid chromatographic (RP-HPLC) method for rapamycin. Separation was performed on a C8 column (MZ, 15 × 4.6 mm, 5 µm particle size) using methanol:water (80:20 v/v) as the mobil...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 42 9 شماره
صفحات -
تاریخ انتشار 1996