A mechanically detachable coil for the treatment of aneurysms and occlusion of blood vessels.
نویسندگان
چکیده
PURPOSE To evaluate mechanically detachable coil designs capable of controlled and instantaneous release within an aneurysm or vascular space. METHODS Three mechanically detachable coil designs, clamped ball, looped ribbon, and interlocking cylinder, were evaluated using in vitro and in vivo testing to study reliability of coil release, retractability, and coil behavior in a microcatheters. In vitro tests were performed using a glass side-wall aneurysm model and conventional microcatheters. In vivo experiments in rabbits included aneurysm models (side-wall and bifurcation) and arterial occlusions (carotid and renal). RESULTS All three designs deployed coils easily and were able to retract coils after partial deployment. Motion was seen in previously released coils and in the catheter when using the clamped ball and looped ribbon designs. The interlocking cylinder design did not cause similar motion. When compared with the other two designs, the interlocking cylinder had significantly greater separation forces between coil pusher and coil while in the catheter. Frictional forces within the catheter were lower for the interlocking cylinder mechanically detachable coil design than for a commercially available conventional coil and coil pusher system. During in vivo testing, the mechanically detachable coil design operated smoothly in the catheter, providing good release and retraction in aneurysms and straight vessels. CONCLUSION The interlocking cylinder mechanically detachable coil design is superior to the other two tested designs. The mechanically detachable coil was reliably delivered and detached in in vivo testing for the treatment of aneurysms and for the occlusion of blood vessels.
منابع مشابه
Anatomically conformable, three-dimensional, detachable platinum microcoil system for the treatment of intracranial aneurysms.
BACKGROUND AND PURPOSE The configurations of detachable platinum coils have evolved over the last decade. Our objective was to assess the efficacy of the anatomically conformable three-dimensional (ACT) detachable platinum microcoil in the treatment of intracranial aneurysms. METHODS A series of 141 patients presented between May 2000 and August 2002 to a single neurointerventionalist for end...
متن کاملGuglielmi detachable coil embolization of posterior circulation aneurysms: a systematic review of the literature.
BACKGROUND Early multicenter trials of Guglielmi detachable coil embolization of posterior circulations aneurysms have been followed by the publication of numerous single-center experiences. Summary of Review- We performed a MEDLINE literature search and extracted data from single-center reports containing at least 10 posterior circulation aneurysms. Twelve reports (495 aneurysms) were specific...
متن کاملCoil embolization for the treatment of ruptured dissecting vertebral aneurysms.
BACKGROUND AND PURPOSE Proximal occlusion of the parent artery has been widely used for treatment of vertebral dissecting ruptured aneurysms, but this does not always completely prevent rerupture. We retrospectively studied 24 consecutive patients for clinical characteristics and/or for efficacy of occlusion with detachable coils at the site of dissection. METHODS During a 45-month period, 24...
متن کاملTopic review: surface modifications enhancing biological activity of guglielmi detachable coils in treating intracranial aneurysms.
BACKGROUND Endovascular therapy with Guglielmi detachable coils is an accepted treatment option for patients with intracranial aneurysms. However, an emerging technology in the realm of endovascular tools is the use of traditional Guglielmi detachable coils with biologically active substances complexed to the coil surface to enhance aneurysm occlusion. METHODS We review the literature and cur...
متن کاملCoil embolization of aneurysms: angiographic and histologic changes.
Coil embolization for aneurysms has been shown to be highly effective treatment to prevent acute recurrent hemorrhages (F. Viñuela, “Summary of the Multicentric Study Results of the Treatment of Cerebral Aneurysms using the GDC System,” presented at the 33rd Annual Meeting of the American Society of Neuroradiology, Chicago, Ill, April 1995). The long-term durability is increasingly important as...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 15 5 شماره
صفحات -
تاریخ انتشار 1994