Suppression of ring artefacts when tomographing anisotropically attenuating samples.

نویسندگان

  • Sofya Titarenko
  • Valeriy Titarenko
  • Albrecht Kyrieleis
  • Philip J Withers
  • Francesco De Carlo
چکیده

There are many objects for which the attenuation varies significantly as they are rotated during computerized X-ray tomography, for example plate samples. This can lead to significant ring artefacts in the subsequent tomographic reconstructions. In this paper a new method is presented that can successfully suppress such ring artefacts and is applicable to both parallel and cone-beam geometries. Rapid correction is achieved via an analytical formula which involves only a matrix-vector multiplication, for which the matrix is known and depends on a regularization parameter. The efficacy of the method is demonstrated for a paleontological sample (calcified shark cartilage) and a carbon-carbon composite/Ti-SiC metal matrix composite test sample.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ring artefact in multidetector CT.

To cite: Artul S. BMJ Case Rep Published online: [please include Day Month Year] doi:10.1136/bcr-2013201379 DESCRIPTION High-resolution tomographic images acquired with a digital X-ray detector are often degraded by the so-called ring artefacts. Ring artefacts are the concentric rings superimposed on tomographic images. Artefacts in general can seriously degrade the quality of multidetector CT ...

متن کامل

Phase contrast in laboratory-based X-ray CT

When scanning weakly attenuating samples using an X-ray tube with a very small focal spot size, the acquired projections not only contain absorption contrast, but also phase contrast due to refraction of the X-rays. Although the resulting edge enhancement can be beneficial in radiography, the tomographic reconstruction of such mixed projections using a conventional algorithm yields cross-sectio...

متن کامل

Psvd-xcca to Suppress Ocular Artefacts in Eeg

In this paper we present a technique to suppress ocular artefacts in the EEG (electroencephalogram) based on a combination of local and global correction algorithms. The results are promising when considering distortion, interference and artefact suppression ratios.

متن کامل

Reduction of ring artefacts in high resolution micro-CT reconstructions.

High resolution micro-CT images are often corrupted by ring artefacts, prohibiting quantitative analysis and hampering post processing. Removing or at least significantly reducing such artefacts is indispensable. However, since micro-CT systems are pushed to the extremes in the quest for the ultimate spatial resolution, ring artefacts can hardly be avoided. Moreover, as opposed to clinical CT s...

متن کامل

When is the ring of real measurable functions a hereditary ring?

‎Let $M(X‎, ‎mathcal{A}‎, ‎mu)$ be the ring of real-valued measurable functions‎ ‎on a measure space $(X‎, ‎mathcal{A}‎, ‎mu)$‎. ‎In this paper‎, ‎we characterize the maximal ideals in the rings of real measurable functions‎ ‎and as a consequence‎, ‎we determine when $M(X‎, ‎mathcal{A}‎, ‎mu)$ is a hereditary ring.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of synchrotron radiation

دوره 18 Pt 3  شماره 

صفحات  -

تاریخ انتشار 2011