Does defibrillation threshold increase as left ventricular ejection fraction decreases?

نویسندگان

  • Jesus E. Val-Mejias
  • Ashish Oza
چکیده

AIMS Advanced cardiac disease, entailing more hypertrophy, fibrosis, scarring, dilatation and conduction delays, poses the question of whether defibrillation thresholds (DFTs) increase as left ventricular ejection fraction (LVEF) decreases. This question has been approached indirectly or insufficiently in previous studies. In this study we add and expand on our previous work, stratifying DFT for various LVEF ranges. METHODS AND RESULTS This retrospective analysis included DFT data from three acute, multicentre, randomized studies that included 230 ICD/CRT-D patients. All DFTs were obtained with the SVC coil turned ON and with pulse-width optimized waveforms based on a 3.5 ms membrane time constant. As the LVEF decreased, DFT estimates increased from 395.2 +/- 115 V for LVEF > or = 46% to 425.8 +/- 117.6 V for LVEF < or = 25%. However, these changes in DFT estimates were very minor and not statistically significant. Only 3% of the patients in this population had an elevated DFT of >20 J. CONCLUSION This analysis shows that over a very broad range of LVEF, DFT changes minimally (approximately 1 J), if at all. Our results are consistent with previous studies that demonstrated no difference in the DFT estimates: (a) between patient groups receiving ICD (typically higher LVEF) vs. CRT-D (typically lower LVEF) and (b) between patient groups receiving a device for primary prevention indications (typically lower LVEF) vs. secondary prevention indications (typically higher LVEF).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of eight weeks of moderate-intensity endurance training on myocardial capillary density, ejection fraction and left ventricular shortening fraction in male rats with myocardial infarction

Background and objective: Vascular obstruction and impaired blood flow and oxygen delivery cause a myocardial infarction and limit a personchr('39')s function. Therefore, finding a way to create new arteries and replace blocked arteries has always been of interest to researchers, including exercise physiologists. Therefore, this study was conducted to evaluate the effect of eight weeks of moder...

متن کامل

Comparison of defibrillation efficacy using implantable cardioverter-defibrillator with single- or dual-coil defibrillation leads and active can.

INTRODUCTION The reduction of defibrillation threshold (DFT) in patients treated with an implantable cardioverter-defibrillator increases patients' safety and prolongs ICD battery life. AIM To evaluate the possibility of reducing the defibrillation threshold in ICDs with an active can and an additional atrial defibrillation coil instead of the typical intracardiac single-coil lead. METHOD T...

متن کامل

Is haemodynamic evaluation with impedance cardiography in patients with heart failure undergoing testing of the implanted cardioverter-defibrillator of clinical importance?

BACKGROUND Identification of individual factors associated with high defibrillation threshold (DFT) seems to be of high clinical importance. Impedance cardiography (ICG) may be used for non-invasive evaluation of the haemodynamic status. Whether ICG parameters may improve identification of patients with high DFT has not yet been examined. AIM To evaluate clinical risk factors of high DFT incl...

متن کامل

Ventricular Fibrillation Terminated by the Seventh Shock

A 49-year-old man consulted our department 3 months after having several implantable cardioverter-defibrillator (ICD) shocks with subsequent syncope. A CRT-D device (Boston Scientific, Cognis 100-D) and a single-element subcutaneous array (Medtronic, model 6996 SQ) had been implanted 2 years previously for primary prevention of sudden cardiac death caused by symptomatic (New York Heart Associat...

متن کامل

Seventh try's a charm: ventricular fibrillation terminated by the seventh shock.

A 49-year-old man consulted our department 3 months after having several implantable cardioverter-defibrillator (ICD) shocks with subsequent syncope. A CRT-D device (Boston Scientific, Cognis 100-D) and a single-element subcutaneous array (Medtronic, model 6996 SQ) had been implanted 2 years previously for primary prevention of sudden cardiac death caused by symptomatic (New York Heart Associat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2010