Meniscal tear film fluid dynamics near Marx's line.
نویسندگان
چکیده
Extensive studies have explored the dynamics of the ocular surface fluid, though theoretical investigations are typically limited to the use of the lubrication approximation, which is not guaranteed to be uniformly valid a-priori throughout the tear meniscus. However, resolving tear film behaviour within the meniscus and especially its apices is required to characterise the flow dynamics where the tear film is especially thin, and thus most susceptible to evaporatively induced hyperosmolarity and subsequent epithelial damage. Hence, we have explored the accuracy of the standard lubrication approximation for the tear film by explicit comparisons with the 2D Navier-Stokes model, considering both stationary and moving eyelids. Our results demonstrate that the lubrication model is qualitatively accurate except in the vicinity of the eyelids. In particular, and in contrast to lubrication theory, the solution of the full Navier-Stokes equations predict a distinct absence of fluid flow, and thus convective mixing in the region adjacent to the tear film contact line. These observations not only support emergent hypotheses concerning the formation of Marx's line, a region of epithelial cell staining adjacent to the contact line on the eyelid, but also enhance our understanding of the pathophysiological consequences of the flow profile near the tear film contact line.
منابع مشابه
Quan Deng
This thesis deals with an interesting application of mathematics, tear film dynamics. Our goal is to understand and simulate the various observed tear film behaviors, such as film cooling, black line formation and lipid patterns etc. During this process, we build models to describe the fluid dynamics for several blink cycles, experiment on the choices of parameters, compare the simulation with ...
متن کاملMeniscal tear as potential steering factor for inflammation may aggravate arthritis: two case reports
INTRODUCTION Meniscal tear is thought to play a crucial role in onset as well as progression of arthritis. However, role of cytokine response to meniscal injury and resulting inflammation is not clearly understood. Because synovial fluid is juxtaposed to cartilage and serves as a biological connection between chondrocytes and synoviocytes, we chose synovial fluid analysis to ascertain biochemic...
متن کاملJoint Line Fullness and Meniscal Pathology
BACKGROUND Meniscal tears have been associated with meniscal cysts and fullness of the knee joint line on physical examination. HYPOTHESIS Joint line fullness is an accurate, sensitive, and specific test to detect meniscal tears. STUDY DESIGN Prospective cohort study. METHODS One hundred consecutive patients undergoing knee arthroscopy were included. All had physical examinations document...
متن کاملARTHROSCOPIC MODIFIED ALL-INSIDE LATERAL MENISCAL TEAR REPAIR USING TWO POSTERIOR PORTAL TECHNICAL NOTE
This was Presented in 5th International Congress of Iranian Iranian Society of Knee Surgery, Arthroscopy, and Sports Traumatology (ISKAST), 14-17 Feb 2018- Kish, Iran
متن کاملThin film dynamics on a prolate spheroid with application to the cornea
The tear film on the front of the eye is critical to proper eyesight; in many mathematical models of the tear film, the tear film is assumed to be on a flat substrate. We re-examine this assumption by studying the effect of a substrate which is representative of the human cornea. We study the flow of a thin fluid film on a prolate spheroid which is a good approximation to the shape of the human...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Bulletin of mathematical biology
دوره 75 9 شماره
صفحات -
تاریخ انتشار 2013