Evaluation of two surgical techniques for acetabular reconstruction in total hip replacement for congenital hip disease: results after a minimum ten-year follow-up.
نویسندگان
چکیده
We have evaluated the results of total hip replacement in patients with congenital hip disease using 46 cemented all-polyethylene Charnley acetabular components implanted with the cotyloplasty technique in 34 patients (group A), and compared them with 47 metal-backed cementless acetabular components implanted without bone grafting in 33 patients (group B). Patients in group A were treated between 1988 and 1993 and those in group B between 1990 and 1995. The mean follow-up for group A was 16.6 years (12 to 18) and the mean follow-up for group B was 13.4 years (10 to 16). Revision for aseptic loosening was undertaken in 15 hips (32.6%) in group A and in four hips (8.5%) in group B. When liner exchange was included, a total of 13 hips were revised in group B (27.7%). The mean polyethylene wear was 0.11 mm/yr (0.002 to 0.43) and 0.107 mm/yr (0 to 0.62) for groups A and B, respectively. Polyethylene wear in group A was associated with linear osteolysis, and in group B with expansile osteolysis. In patients with congenital hip disease, when 80% cover of the implant can be obtained, a cementless acetabular component appears to be acceptable and provides durable fixation. However, because of the type of osteolysis arising with these devices, early exchange of a worn liner is recommended before extensive bone loss makes revision surgery more complicated.
منابع مشابه
Reconstruction of the Acetabulum in Developmental Dysplasia of the Hip in Total Hip Replacement
Developmental dysplasia of the hip (DDH) or congenital hip dysplasia (CDH) is the most prevalent developmental childhood hip disorder. It includes a wide spectrum of hip abnormalities ranging from dysplasia to subluxation and complete dislocation of the hip joint. The natural history of neglected DDH in adults is highly variable. The mean age of onset of symptoms is 34.5 years for dysplastic DD...
متن کاملTotal hip replacement with a superolateral bone graft for osteoarthritis secondary to dysplasia: a long-term follow-up.
We evaluated the long-term results of 116 total hip replacements with a superolateral shelfplasty in 102 patients with osteoarthritis secondary to developmental dysplasia of the hip. After a mean follow-up of 19.5 years (11.5 to 26.0), 14 acetabular components (12%) had been revised. The cumulative survival at 20 years was 78%, with revision for loosening of the acetabular component as the end-...
متن کاملUncemented Total Hip Replacement After Two Years of Neglected Hip Dislocation With Fracture of Posterior Column and Wall of the Acetabulum
INTRODUCTION Posterior hip dislocation of the hip with acetabular fracture is a challenging problem to treat. Such dislocations are associated with avascular necrosis of the femoral head if neglected. Managing such conditions with total hip replacement (THR) is very difficult because of associated altered anatomy. CASE PRESENTATION We hereby report a two-year neglected hip dislocation with as...
متن کاملA minimum three-year clinical and radiological follow up of the utilisation of a Cementless Multihole Mega cups in conversion hip arthroplasty--a prospective analysis.
UNLABELLED The introduction of multihole mega cup has proposed innovative answers in the management of acetabular impediments that ensued from the use of bipolar hemiarthroplasty. This study bestows a prospective analysis of the outcome of conversion surgery from bipolar hemiarthroplasty to total hip replacement in patients with acetabular complications.Forty-two patients, 22 men and 20 women, ...
متن کاملThe Trabecular Metal Monoblock acetabular component in patients with high congenital hip dislocation: a prospective study.
Between November 1997 and December 2000 we performed 27 total hip replacements in 22 patients with high congenital dislocation of the hip using porous tantalum monoblock acetabular components implanted in the true acetabular bed. Clinical and radiological evaluation was performed at regular intervals for a mean of 10.2 years (8.5 to 12). The mean Harris Hip Score improved from 48.3 (15 to 65) p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of bone and joint surgery. British volume
دوره 90 6 شماره
صفحات -
تاریخ انتشار 2008