Audit of nebuliser use.

نویسندگان

  • P E Williams
  • S A Renowden
  • M J Ward
چکیده

The use of nebulisers was assessed in four hospitals. Nebulisers were checked in use and medical and nursing staff were interviewed. All but one nebuliser was driven by 100% oxygen and only 3 of 111 interviewees preferred air for patients with hypercapnia. In 5 of 44 nebulisers in use, water was used as the dilutant. The calculated times for complete nebulisation of the solutions ranged from 3.5 to 117 min. The results of this survey illustrate a need for better education concerning the use of nebulisers in hospitals.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Alcohol Use Disorders Identification Test (AUDIT): Reliability and Validity of the Persian version

Background: Alcohol Use Disorders (AUDs) has been recently prioritized as a health problem in Iran. The Alcohol Use Disorders Identification Test (AUDIT) is an easy-to-use diagnostic tool for excessive drinking. This study was designed to assess the validity and reliability of the Persian version of AUDIT questionnaire. Methods: Participants were 70 individuals with AUD (study group) and 70 non...

متن کامل

Randomised crossover trial of salbutamol aerosol delivered by metered dose inhaler, jet nebuliser, and ultrasonic nebuliser in chronic lung disease.

AIMS To compare the efficacy of salbutamol delivered by metered dose inhaler (MDI), jet nebuliser, and ultrasonic nebuliser in ventilated infants with chronic lung disease. METHODS Twenty preterm ventilated infants with chronic lung disease were enrolled in two studies. In study 1 (n = 10), each infant was given 200 micrograms of salbutamol at 4 hour intervals and in random sequence from a me...

متن کامل

Running a domiciliary nebuliser service.

A nebuliser service should be provided locally, according to local needs. It should be centralised and administered by a designated consultant or consultants and written guidelines should be provided for medical and para-medical staff. The service should: (1) provide compressor/nebuliser units suitable for the prescribed treatment, (2) provide a system for equipment replacement, repair and main...

متن کامل

Asthma management in accident and emergency and the BTS guidelines--a study of the impact of clinical audit.

OBJECTIVE To determine whether the care of asthma patients in accident and emergency Departments (A&E) is improved by clinical audit of asthma management. METHODS The quality of care during continuous cycles of clinical audit was compared with that one year later, after an audit programme had ended and most of the medical staff had changed. This was done by a retrospective case notes review o...

متن کامل

A national survey of nebuliser use.

Nebuliser drug delivery units were reused in 15% of paediatric wards participating in a national survey, while routine servicing and written information was provided by only half the wards issuing home nebulisers. Written information should be developed as a national resource, and further research on optimal cleaning practices is required.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Postgraduate medical journal

دوره 61 722  شماره 

صفحات  -

تاریخ انتشار 1985