Preconcentration and determination of mercury(II) at a chemically modified electrode containing 3-(2-thioimidazolyl)propyl silica gel.

نویسندگان

  • Newton L Dias Filho
  • Devaney R do Carmo
  • Laércio Caetano
  • André H Rosa
چکیده

A mercury-sensitive chemically modified graphite paste electrode was constructed by incorporating modified silica gel into a conventional graphite paste electrode. The functional group attached to the (3-chloropropyl) silica gel surface was 2-mercaptoimidazole, giving a new product denoted by 3-(2-thioimidazolyl)propyl silica gel, which is able to complex mercury ions. Mercury was chemically adsorbed on the modified graphite paste electrode containing 3-(2-thioimidazolyl)propyl silica (TIPSG GPE) by immersion in a Hg(II) solution, and the resultant surface was characterized by cyclic and differential pulse anodic stripping voltammetry. One cathodic peak at 0.1 V and other anodic peak at 0.34 V were observed on scanning the potential from -0.1 to 0.8 V (0.01 M KNO3; v = 2.0 mV s(-1) vs. Ag/AgCl). The anodic peak at 0.34 V show an excellent sensitivity for Hg(II) ions in the presence of several foreign ions. A calibration graph covering the concentration range from 0.02 to 2 mg L(-1) was obtained. The detection limit was estimated to be 5 microg L(-1). The precision for six determinations of 0.05 and 0.26 mg L(-1) Hg(II) was 3.0 and 2.5% (relative standard deviation), respectively. The method can be used to determine the concentration of mercury(II) in natural waters contaminated by this metal.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Hg in water by CVAAS using 2-aminothiazole modified silica

This paper discusses a rapid and sensitive method developed to determine trace levels of mercury in natural water samples by cold vapor atomic absorption spectrometry using a preconcentration system composed by mini-column packed with 100 mg of 2-aminothiazol modified silica gel (SiAT) coupled on-line with the spectrometer’s cold vapor generator system. The optimum preconcentration conditions a...

متن کامل

Controlled-pore silica glass modified with N-propylsalicylaldimine for the separation and preconcentration of trace Al(III), Ag(I) and Hg(II) in water samples.

Controlled-pore silica glass modified with N-propylsalicylaldimine (SCPSG) has been investigated as a surface-active matrix for the separation of some metal ions. The porous silica glass base was confirmed to have better stability towards hydrolysis in aqueous solution buffered at pH=9 in comparison to silica gel, which showed twice the surface area of controlled-pore silica glass. The differen...

متن کامل

Preparation of a clay-modified carbon paste electrode based on 2-thiazoline-2-thiol-hexadecylammonium sorption for the sensitive determination of mercury.

A montmorillonite from Wyoming-USA was used to prepare an organo-clay complex, named 2-thiazoline-2-thiol-hexadecyltrimethylammonium-clay (TZT-HDTA-clay), for the purpose of the selective adsorption of the heavy metals ions and possible use as a chemically modified carbon paste electrode (CMCPE). Adsorption isotherms of Hg2+, Pb2+, Cd2+, Cu2+, and Zn2+ from aqueous solutions as a function of th...

متن کامل

Cold Vapor Atomic Absorption Determination of Hg in Crude Oil and Gasoline Samples after Solid Phase Extraction Using Modified Disks

A facile and highly efficient method have been developed for the preconcentration of the mercury content in crude oil and gasoline samples after digestion with microwave-assisted digestion. Octadecyl silica membrane disk has been modified by the recently synthesized triazene ligand, (E)-1-(2-ethoxyphenyl)-3-(4-nitrophenyl) triaz-1-ene (ENT), then the modified membrane was used for the preco...

متن کامل

Voltammetric detection of lead(II) and mercury(II) using a carbon paste electrode modified with thiol self-assembled monolayer on mesoporous silica (SAMMS).

The anodic stripping voltammetry at a carbon paste electrode modified with thiol terminated self-assembled monolayer on mesoporous silica (SH-SAMMS) provides a new sensor for simultaneous detection of lead (Pb2+) and mercury (Hg2+) in aqueous solutions. The overall analysis involved a two-step procedure: an accumulation step at open circuit, followed by medium exchange to a pure electrolyte sol...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 21 11  شماره 

صفحات  -

تاریخ انتشار 2005