Biomechanical comparison of fixation of type-I fractures of the lateral tibial plateau.

نویسنده

  • J W Tan
چکیده

Type-I fractures of the lateral tibial plateau were simulated by osteotomy in 18 pairs of unembalmed cadaver tibiae. One fracture of each pair was fixed with two lag screws whereas the contralateral site was stabilised with three lag screws, or two lag screws plus an antiglide screw. The lateral plateau was displaced downwards using a servohydraulic materials testing machine and the resulting force and articular surface gap were recorded. Yield load was defined as the maximum load needed to create a 2.0 mm articular offset at the fracture line. The yield loads of the three-lag-screw (307 +/- 240 N) and antiglide constructs (342 +/- 249 N) were not significantly different from their two-screw control constructs (231 +/- 227 and 289 +/- 245 N, respectively). We concluded that adding an antiglide screw or a third lag screw did not provide any biomechanical advantage in stabilising these fractures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Challenges of Plate Fixation for Vancouver Type-C Fractures after a Well-Fixed Hip Arthroplasty Femoral Stem

The fixation of distal femoral fractures (Vancouver type-C fractures) following a well-fixed hip arthroplasty femoral stem has become a challenging issue for orthopedic surgeons due to the inter-prosthetic biomechanical effects such as negative, positive, and torsional strain. Surgeons have applied a range of constructs to overcome these difficulties. To minimize the risk of inter-prosthetic fr...

متن کامل

A biomechanical study comparing two fixation methods in depression fractures of the lateral tibial plateau in porcine bone

BACKGROUND A novel method of fixation has been described for the treatment of pure depression fractures of the lateral tibial plateau. Fracture fragments are elevated through a reamed transtibial tunnel. An interference screw is then passed into the tunnel to buttress fracture fragments from beneath. This method of fixation has perceived benefits but there have been no studies to demonstrate th...

متن کامل

Functional Outcome and Incidence of Osteoarthritis in Operated Tibial Plateau Fractures

Background: In the challenging tibial condyle fractures despite anatomical joint reconstruction, development ofosteoarthritis may still occur secondary to the initial articular cartilage and meniscal injury. The aim of the study wasto know incidence of osteoarthritis in our operated cases of tibial plateau fracture and to evaluate functional outcome.Methods: Our operated 60 patients of tibial p...

متن کامل

Treatment of Open Tibial Fractures: Convert-ing or Continuing External Fixation?

Background: The treatment of open tibial fractures is still an orthopaedic challenge and full of complications. In many cases the use of external fixator that has been known as a non-union machine is obligatory with a high incidence of pin track infection and other complications. The aim of this study was to compare the use of external fixation as a definite method for treatment of open tibial ...

متن کامل

The Efficacy of Meniscal Treatment Associated with Lateral Tibial Plateau Fractures

Purpose The purpose of this study was to examine the incidence of lateral meniscal tears associated with lateral tibial plateau fractures and report the clinical outcomes of meniscal treatment with internal fixation of fractures. Materials and Methods All lateral tibial plateau fractures (Schatzker types II and III) in skeletally mature patients treated operatively at our institution between ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 82 1  شماره 

صفحات  -

تاریخ انتشار 1999