Compact optical integration instrument to measure intraocular straylight.
نویسندگان
چکیده
Optical measurement of straylight in the human eye is a challenging task. Issues such as illumination geometry, detector sensitivity and dynamic range as well as various inherent artifacts must be addressed. We developed a novel instrument based on the principle of double-pass optical integration adapted for fast measurements in a clinical setting. The experimental setup was validated using four different diffusers introduced in front of the eyes of ten subjects. Measurement limitations and future implications of rapid optical measurement of straylight in ophthalmic diagnosis are discussed.
منابع مشابه
Optical Measurement of Straylight in Eyes With Cataract.
PURPOSE To measure straylight in a cohort of patients with cataract using a novel optical instrument and to correlate optical straylight values with clinical grade of cataracts and psychophysical straylight values. METHODS Measurements were performed on 53 eyes of 44 patients with cataract admitted to the ophthalmology service of the university hospital in Murcia, Spain, and 9 young volunteer...
متن کاملEnvironmental and Genetic Factors Explain Differences in Intraocular Scattering.
PURPOSE To study the relative impact of genetic and environmental factors on the variability of intraocular scattering within a classical twin study. METHODS A total of 64 twin pairs, 32 monozygotic (MZ) (mean age: 54.9 ± 6.3 years) and 32 dizygotic (DZ) (mean age: 56.4 ± 7.0 years), were measured after a complete ophthalmologic exam had been performed to exclude all ocular pathologies that i...
متن کاملEffect of diabetic retinopathy and diabetes on the intraocular straylight in pseudophakic eyes
BACKGROUND The aim of this study was to prove the relationship between the intraocular straylight level and diabetic retinopathy (DR) according to disease severity. Also, we aimed to evaluate whether diabetes mellitus (DM) per se could be a risk factor of increased intraocular straylight although we did not rely on a definite sign of DR in this study. METHODS In this prospective comparative s...
متن کاملOptical Scattering Measurements of Laser Induced Damage in the Intraocular Lens
This study optically determines whether the amount of light scatter due to laser-induced damage to the intraocular lens (IOL) is significant in relation to normal straylight values in the human eye. Two IOLs with laser-induced damage were extracted from two donor eyes. Each IOL had 15 pits and/or cracks. The surface area of each pit was measured using a microscope. For 6 pits per intraocular le...
متن کاملComparison of ocular straylight after implantation of multifocal intraocular lenses.
UNLABELLED A comprehensive review of the effect of multifocal intraocular lens (IOL) designs on postoperative ocular straylight was performed. Studies reporting straylight values obtained with the natural pupil using the C-Quant device after uneventful multifocal IOL implantation were included. The IOLs were categorized based on their material characteristics; that is, hydrophobicity and presen...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Biomedical optics express
دوره 5 9 شماره
صفحات -