Accuracy of PlusOptix A09 distance refraction in pediatric myopia and hyperopia

نویسندگان

  • Arnaud Payerols
  • Claudie Eliaou
  • Véronique Trezeguet
  • Max Villain
  • Vincent Daien
چکیده

BACKGROUND The PlusOptix photoscreeners (PlusOptix GmbH, Nuremberg, Germany) is used in many vision screening programs. The purpose of the present study was to further explore the accuracy of the PlusOptix A09 photoscreener in children with ametropia (myopia or hyperopia). METHODS A total of 70 eyes (35 children) were prospectively included. Before administration with the cycloplegia treatment 1 % cyclopentolate hydrochloride, children underwent refraction measurement with the PlusOptix A09. A refraction was then performed after cycloplegia with either Retinomax hand-held or Nidek autorefractor before and after 3 years old, respectively. RESULTS The median (interquartile range) age was 58 (18 to 86) months. The mean (SD) spherical equivalent differed between PlusOptix A09 and cycloplegic autorefraction (+0.54 [1.82] D vs +1.06 [2.04] D, p = 0.04). PlusOptix A09 refraction was positively correlated with cycloplegic autorefraction (r = 0.81, p < 0.001) with higher coefficient in myopic than in hyperopic children (r = 0.91, p = 0.0002 and r = 0.52, p = 0.01, respectively). The mean (SD) difference between PlusOptix A09 and cycloplegic autorefraction was higher with hyperopia than myopia (0.73 [1.34] vs 0.05 [0.66], p = 0.01). The proportion of children with < 1-D difference between cycloplegic and PlusOptix A09 refraction was 68.8 %, higher with myopia than hyperopia (90 % vs 54.5 %, p = 0.01). CONCLUSION The spherical equivalent value with non-cycloplegic PlusOptix A09 refraction is closer to that with cycloplegic autorefraction than non-cycloplegic autorefraction. The PlusOptix A09 photoscreener underestimated the hyperopia of 0.73 D and slightly overestimated myopia of 0.05 D. The PlusOptix A09 could be used for screening with higher accuracy in myopic than hyperopic children.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance of the Plusoptix A09 Photoscreener in Detecting Amblyopia Risk Factors in Chinese Children Attending an Eye Clinic

PURPOSE To assess the accuracy of the Plusoptix A09 photoscreener in detecting amblyopia risk factors in children and determine referral criteria when using Plusoptix A09 for a large-scale vision screening. METHODS Pediatric patients attending our eye clinic underwent a comprehensive ophthalmic examination that included photorefraction, orthoptic examination, anterior segment assessment, fund...

متن کامل

ROC Analysis to Improve Sensitivity and Specificity of the PlusoptiX Photoscreener

The current issue of JOVR includes an article entitled “Is Noncycloplegic Photorefraction Applicable for Screening Refractive Amblyopia risk Factors?”.1 This is a well-constructed study comparing noncycloplegic photorefraction uti l izing the plusoptiX SO4 screener to cycloplegic autorefraction (or cycloplegic retinoscopy in those few children in whom cycloplegic autorefraction could not be per...

متن کامل

Is Noncycloplegic Photorefraction Applicable for Screening Refractive Amblyopia Risk Factors?

PURPOSE To compare the accuracy of noncycloplegic photorefraction (NCP) with that of cycloplegic refraction (CR) for detecting refractive amblyopia risk factors (RARFs) and to determine cutoff points. METHODS In this diagnostic test study, right eyes of 185 children (aged 1 to 14 years) first underwent NCP using the PlusoptiX SO4 photoscreener followed by CR. Based on CR results, hyperopia (≥...

متن کامل

A comparison of the Plusoptix S09 with an autorefractometer of noncycloplegics and cycloplegics in children

The aim of the study is to compare outcome measures of refractive error obtained using the Plusoptix S09 photorefractor and an autorefractometer of noncycloplegics and cycloplegics in children.We reviewed the medical records of 40 patients (77 eyes) who were classified using 2 methods. The patients were first assigned to 2 groups consisting of 11 eyes with ≥+3.0 D and 66 eyes with <+3.0 D, and ...

متن کامل

Accuracy and Repeatability of Refractive Error Measurements by Photorefractometry

PURPOSE To determine the accuracy of photorefraction and autorefraction as compared to cycloautorefraction and to detect the repeatability of photorefraction. METHODS This diagnostic study included the right eyes of 86 children aged 7-12 years. Refractive status was measured using photorefraction (PlusoptiX SO4, GmbH, Nürnberg, Germany) and autorefraction (Topcon RM800, USA) with and without ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2016