The prognostic value of tip-to-apex distance (TAD index) in intertrochanteric fractures fixed by dynamic hip screw

نویسندگان

  • Ali Sedighi
  • Jafar Ganjpour Sales
  • Sahar Alavi
چکیده

Intertrochanteric fractures (ITFs) are the most common type of fractures requiring surgical intervention. They also have the highest surgical mortality among orthopedic operations. Among the many different techniques used for fixation of this type of fracture, use of the Dynamic Hip Screw (DHS) has gained wide acceptance. This current study was designed to assess positive predictive value of tip-to-apex distance (TAD) index in the prognosis of patients treated with DHS. The study was designed according to a descriptive-analytic protocol, made up of 100 cases of ITFs caused by falling, treated in the Shohada Orthopedic Center, Tabriz, Iran. All patients underwent lateral and antero-posterior hip X-ray to measure TAD index. The cohort was followed for three months after DHS placement. Of a total of 100 cases (53 male, 47 female) with a mean age of 76.7 years (range 29-100 years), 43% had grade 4, 29% grade 3, 21% grade 5, 5% grade 2 and 2% grade 6 osteoporosis. The screw position was postero-inferior in 57%, central in 40% and superior in 3% of patients. Minimum and maximum TAD index were 20 and 28 mm, respectively. Mean TAD was 23.5 mm. There were no post-operative complications in 84% of cases. Screw failure was the most common complication in the remaining 16% of patients. The study shows a statistically significant correlation between TAD index and cut-off rate in patients with intertrochanteric fractures of femoral bone treated by DHS. This validates the use of TAD index in determining the prognosis of patients treated by DHS.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tip Apex Distance: a useful method to assess extra-capsular neck of femur fixation?

The Tip Apex Distance (TAD) is a simple measurement that predicts screw cut-out in the femoral head from trochanteric fractures treated with a fixed angle sliding hip screw device [1]. It uses a numerical value to show placement of the screw in the head: higher values indicating higher likelihood of fixation failure by extrusion of the screw. Currently the cost of hip fracture care in the UK is...

متن کامل

Dynamic hip screw fixation of intertrochanteric fractures without using traction table.

To evaluate a new technique of Dynamic hip screw (DHS) fixation without using traction table. From july 2006 to july 2012, 328 patients undergoing DHS fixation using manual traction technique were evaluated in terms of Tip apex distance (TAD), -quality of fracture reduction, operation time, preoperative preparation time. In 97% cases good to moderate reduction could be achieved. The mean TAD wa...

متن کامل

A double-blind, prospective, randomised, controlled clinical trial of minimally invasive dynamic hip screw fixation of intertrochanteric fractures.

OBJECTIVE To compare minimally invasive dynamic hip screw (MIDHS) fixation with conventional dynamic hip screw (CDHS) fixation for treatment of intertrochanteric femoral fracture. METHODS Of the 66 participants in this double-blind study, 35 were randomised to MIDHS and 31 to CDHS fixation. Main outcome measurements were wound size, haemoglobin decrease, blood transfusion rate, pain score, an...

متن کامل

Type II Intertrochanteric Fractures: Proximal Femoral Nailing (PFN) Versus Dynamic Hip Screw(DHS)

  Background: Intertrochanteric fracture is one of the most common fractures of the hip especially in the elderly with osteoporotic bones, usually due to low-energy trauma like simple falls. Dynamic Hip Screw (DHS) is still considered the gold standard for treating intertrochanteric fractures by many. Not many studies compare the DHS with Proximal femoral nail (PFN), in Type II intertrochanteri...

متن کامل

Awareness of tip-apex distance reduces failure of fixation of trochanteric fractures of the hip.

We compared the results of the surgical treatment of trochanteric hip fractures before and after surgeons had been introduced to the tip-apex distance (TAD) as a method of evaluating screw position. There were 198 fractures evaluated retrospectively and 118 after instruction. The TAD is the sum of the distance from the tip of the screw to the apex of the femoral head on anteroposterior and late...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2012