Expression of tenascin-C in aseptic loosening of total hip replacement.

نویسندگان

  • Y T Konttinen
  • T F Li
  • O Michelsson
  • J W Xu
  • T Sorsa
  • S Santavirta
  • S Imai
  • I Virtanen
چکیده

OBJECTIVE To assess if the bonding interlayer between the implant and bone in aseptic loosening of total hip replacement (THR) is qualitatively deteriorated by excessive accumulation of anti-adhesive glycoprotein, tenascin-C. METHODS Alkaline phosphatase-anti-alkaline phosphatase (APAAP) method was used for immunohistochemical staining of tenascin-C in interface tissue and control synovial tissue. RESULTS Tenascin-C was found to be a major component of the extracellular matrix at a hitherto unrecognised site, namely the synovial membrane-like interface tissue between implant and bone in aseptic loosening of THR. The overall tenascin-C staining (median score 4.0) was greatly increased in aseptic loosening compared with synovial membrane (median score 2.0; p < 0.001) and fibrous capsule (median score 2.0; p < 0.001) from primary THR operations. Topological analysis disclosed that tenascin-C was also found at the critical implant-interface and interface-bone surfaces. CONCLUSION Local tenascin-C expression is increased as a result of a chronic foreign body type reaction associated with excessive cytokine production and tissue injury mediated by microtrauma and neutral endoproteinases. This qualitative and topological deterioration of the bonding interlayer by an increase of anti-adhesive tenascin-C expression may inadvertantly contribute to loosening.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The role of reactive oxygen species scavenging enzymes in the development of septic loosening after total hip replacement.

In this study of 41 patients, we used proteomic, Western blot and immunohistochemical analyses to show that several reactive oxygen species scavenging enzymes are expressed differentially in patients with primary osteoarthritis and those with non-loosening and aseptic loosening after total hip replacement (THR). The patients were grouped as A (n = 16, primary THR), B (n = 10, fixed THR but requ...

متن کامل

The BCL2 -938C>A Promoter Polymorphism Is Associated with Risk for and Time to Aseptic Loosening of Total Hip Arthroplasty.

Aseptic loosening is a major cause of revision surgery of total hip arthroplasty (THA). Only few host factors affecting aseptic loosening have been identified until now, although they are urgently needed to identify and possibly treat those patients at higher risk for aseptic loosening. To determine whether the functional single nucleotide polymorphism (SNP) c.-938C>A (rs2279115), located in th...

متن کامل

Total Hip Replacement Revision in a Single Brand Small Cementless Stem – Our Experience after the Findings of the National Joint Registry

Background: Cementless total hip replacement is the common THR performed in England, Wales, Northern Irelandand the Isle of Man. The Corail stem is the most popular cementless implant and has a ODEP 10A rating. Review ofits performance in the registry identified an increase rate of revision amongst the smaller stem sizes. However, claritywas not provided on the explanation for this finding. We ...

متن کامل

Genetic susceptibility to total hip arthroplasty failure: a case–control study on the influence of MMP 1 gene polymorphism

BACKGROUND Genetic factors plays an important role in early failure of total hip arthroplasty (THA) etiology and MMP-1 gene polymorphism rs5854 may be involved. The present study was conducted to reveal the possible association between MMP-1 rs5854 C/T polymorphism and the risk of early failure of THA (aseptic loosening). METHODS The rs5854 single nucleotide polymorphism (SNP) in MMP-1 gene w...

متن کامل

Biomarkers for early diagnosis of aseptic loosening after total hip replacement

Numbers of patients are suffering from aseptic loosening after total hip replacement, which can need further revision surgery. Particle-induced osteolysis has been considered as a major cause of aseptic loosening after hip joint replacement. This is a prospective study, and there are 82 patients of unilateral osseous arthritis and 10 normal physical examination people in our hospital for this s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of the rheumatic diseases

دوره 57 10  شماره 

صفحات  -

تاریخ انتشار 1998