Real-time cerebral angiography: sensitivity of a new contrast-specific ultrasound technique.

نویسندگان

  • T Hölscher
  • J A Sattin
  • R Raman
  • W Wilkening
  • C V Fanale
  • S E Olson
  • R F Mattrey
  • P D Lyden
چکیده

BACKGROUND AND PURPOSE To test a new contrast-specific sonography imaging method that offers visualization of the intracranial vasculature in a manner similar to that seen on angiography. MATERIALS AND METHODS Thirty patients (35 sonography studies total) were included in the study after they provided written informed consent. The patients were scanned through the temporal bone window from both sides after intravenous injection of an ultrasound contrast agent (UCA; perflexane lipid microspheres [Imagent]). The goal was to visualize the intracranial arteries, including the middle (M1-M3), anterior (A1 and A2), and posterior (P1-P3) cerebral arteries, using an axial scanning plane. The studies were performed using a contrast-specific imaging mode, based on a phase inversion technique (transcranial ultrasound angiography [tUSA]). For sensitivity, the results were compared with x-ray angiography as the "gold standard." For interobserver reliability, 24 of 35 sonography studies were evaluated by 2 physicians with little training in transcranial sonography and by a seasoned sonographer. RESULTS The sensitivity of tUSA ranged between 0.778 (95% confidence interval [CI] of 0.577-0.914) and 0.963 (95% CI of 0.810-0.999). The sensitivities were similar among physicians with little training in transcranial sonography and the seasoned sonographer, indicating high inter-rater reliability. Overall, tUSA provided high anatomic resolution and vascular delineation even of small vessels in the millimeter range. At peak intensity, no UCA-related artifacts were observed. CONCLUSION tUSA provides images of the intracranial arteries similar to those obtained at angiography with high anatomic resolution, reasonable sensitivity, and interobserver reliability.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Microscopy Sensitivity, Specificity in Detection of P. falciparum and P. vivax, Using Monoplex real-time PCR, Gezira, Sudan

Background: Malaria is still account for 200 million cases annually. Microscopy is the gold standard technique for malaria parasites detection. PCR-based techniques can detect malaria infections with high sensitivity. The study aimed to evaluate the sensitivity of microscopy technique in the detection of P. falciparum and P. vivax, using monoplex real-time PCR, Gezira State, Central Sudan. Met...

متن کامل

Clinical applications of virtual, non-contrast head images derived from dual-source, dual-energy cerebrovascular computed tomography angiography

Background: This study set out to evaluate the utility of cerebrovascular virtual non-contrast (VNC) scans. Materials and Methods: Conventional non-contrast (CNC) and dual-energy computed tomography angiography (DE-CTA) head scans were conducted on 100 subjects, of which 46 were normal, 15 had parenchymal hematomas of the brain, 13 had ischemic infarction, 22 had tumors, and 4 had calcified les...

متن کامل

Extracranial and intracranial sonographic findings in vertebral artery diseases.

OBJECTIVE The aim of this review is to illustrate the sonographic features that can be detected in vertebral artery (VA) diseases. METHODS We conducted a review of sonographic findings in VA diseases. RESULTS Various VA diseases are described, and sonographic techniques and features are discussed. CONCLUSIONS Posterior circulation vascular imaging can be performed by means of various neur...

متن کامل

Noninvasive detection of vertebral artery stenosis: a comparison of contrast-enhanced MR angiography, CT angiography, and ultrasound.

BACKGROUND AND PURPOSE Vertebral stenosis is associated with a high risk of recurrent stroke, but noninvasive imaging techniques to identify it have lacked sensitivity. Contrast-enhanced MR angiography and CT angiography have been recently developed and appear to have better sensitivity. However, no prospective studies have compared both of these techniques with ultrasound against the gold stan...

متن کامل

Parallel Beamformation Method to Enhance Ultrasound Images

Contrast resolution and detail resolution are two important parameters in ultrasound imaging. This paper presents a new method to enhance these parameters, simultaneously. A parallel auxiliary beamformer has been employed whose weightings are such that an estimation of the leaked signal through the main beamformer is obtained. Then the output of main beamformer is modified according to the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 28 4  شماره 

صفحات  -

تاریخ انتشار 2007