Pacing and defibrillation lead exchange without vein puncture.

نویسندگان

  • Dante Antonelli
  • Nahum A Freedberg
  • Yoav Turgeman
چکیده

BACKGROUND During lead implantation, venous access is generally achieved by puncturing the subclavian or axillary vein. Sometimes, although rarely, after lead positioning, the lead must be changed because of its inadequate mechanical stability or poor pacing parameters. This report concerns a technique of lead exchange that avoids an additional vein puncture. METHOD The tip of the lead, that has to be replaced, is retracted from the right atrium or ventricle into the superior vena cava; the lead insulation is lanced along a few millimeters; the straight flexible tip of the guide wire is inserted between the insulation layer and the conductor of the lead. Then the lead is advanced, while the guide wire is driven in, until the tip of the guide wire is in the superior vena cava. At this point, the tip of the guide wire, gently retracted from its position, is released in the vein lumen. Subsequently, the lead is completely extracted from the vein but the guide wire is maintained inside it. A dilator with a mounted peel-away sheath is advanced over the guide wire. The lead positioning follows in the usual manner. RESULTS Three (2.2%) of the 139 implanted defibrillator leads and 13 (3.3%) of the 391 pacing leads were replaced. All the procedures were successful; their mean time was 2 +/- 1 minutes. CONCLUSION This technique is successful and safe in providing vein access using the previously implanted lead, thus avoiding the need to repeat the puncturing of a vein.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Azygos Vein Lead Implantation For High Defibrillation Thresholds In Implantable Cardioverter Defibrillator Placement

Evaluation of defibrillation threshold is a standard of care during implantation of implantable cardioverter defibrillator. High defibrillation thresholds are often encountered and pose a challenge to electrophysiologists to improve the defibrillation threshold. We describe a case series where defibrillation thresholds were improved after implanting a defibrillation lead in the azygos vein.

متن کامل

Feasibility of peripheral venous access for temporary right ventricular pacing.

INTRODUCTION In this brief report, we present our experience from placing temporary pacing electrodes through peripheral venous access sites, at bedside, in a series of patients needing temporary pacing. METHODS Consecutive patients requiring temporary pacing were selected. The median cubital or the basilic vein of the left upper extremity were used for catheterization at the bedside in all c...

متن کامل

Venous spasm during contrast-guided axillary vein puncture for pacemaker or defibrillator lead implantation.

AIMS Contrast-guided axillary vein puncture is commonly used for pacemaker or defibrillator lead implantation. Venous spasm during contrast-guided axillary vein puncture has been reported rarely. We investigated the incidence of venous spasm during contrast-guided axillary vein puncture and the impact of venous spasm on axillary vein puncture. METHODS AND RESULTS Seventy-four consecutive pati...

متن کامل

A safe and effective method for pacemaker implantation in children Axillary vein puncture for device implantation and use of 4F catheter- delivered pacing leads in children

Background: Contrast-guided axillary vein puncture has gained popularity for pacemaker and implantable cardioverter defibrillator (ICD) implantation in adults owing to its low risk profile, and could be an alternative to subclavian vein puncture, which is commonly performed in children. The Medtronic 3830 lead is a 4.1F lumenless catheter-delivered lead which may be particularly well-suited for...

متن کامل

Rescue permanent iliac vein pacing after epicardial lead failure: an unusual reversal of pacing fortune.

Surgical lead placement is generally considered as a last resort for patients who require permanent pacing and who are unable to accommodate transvenous leads. The technique is limited by the need for direct epicardial access and reduced reliability of epicardial leads (compared with modern transvenous leads) [Belott and Reynolds. Permanent pacemaker and implantable cardioverter defibrillator i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Pacing and clinical electrophysiology : PACE

دوره 32 5  شماره 

صفحات  -

تاریخ انتشار 2009