A Primary Dead-Weight Tester for Pressures (0.05–1.0) MPa

نویسندگان

  • Kamlesh Jain
  • Walt Bowers
  • James W. Schmidt
چکیده

Recent advances in technology on two fronts, 1) the fabrication of large-diameter pistons and cylinders with good geometry, and 2) the ability to measure the dimensions of these components with high accuracy, have allowed dead-weight testers at the National Institute of Standards and Technology (NIST) to generate pressures that approach total relative uncertainties previously obtained only by manometers. This paper describes a 35 mm diameter piston/cylinder assembly (known within NIST as PG-39) that serves as a pressure standard in which both the piston and the cylinder have been accurately dimensioned by Physikalisch Technische Bundesanstalt (PTB). Both artifacts (piston and cylinder) appeared to be round within ±30 nm and straight within ±100 nm over a substantial fraction of their heights. Based on the diameters at 20 °C provided by PTB (±15 nm) and on the good geometry of the artifact, the relative uncertainties for the effective area were estimated to be about 2.2 × 10(-6) (1σ).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Double-Primary Dead-Weight Tester for Pressures (35–175) kPa in Gage Mode

Primary pressure standards in the atmospheric pressure range are often established using mercury manometers. Less frequently, controlled-clearance dead-weight testers in which one component (normally the piston) has been dimensionally measured have also been used. Recent advances in technology on two fronts i) the fabrication of large-diameter pistons and cylinders with good geometry; and ii) t...

متن کامل

Soda lime temperatures during low-flow sevoflurane anaesthesia and differences in dead-space.

BACKGROUND Sevoflurane degrades during low-flow anaesthesia to compound A, and high carbon dioxide absorbent temperatures cause increased degradation. The purpose of this investigation was to determine if larger tidal volumes, without increasing alveolar ventilation, decrease the temperature in the carbon dioxide absorber during low- and minimal-flow sevoflurane anaesthesia. METHODS Prospecti...

متن کامل

Are cells viable at gigapascal pressures?

Sharma et al. (1) claimed that Shewanella oneidensis, which lives in habitats at pressures of around 0.1 megapascals (MPa), is viable at pressures well above 100 MPa. This result stands in marked contrast to all previous studies, which have found viability, defined (2) as growth and division of cells, at pressures above 100 MPa only among the inhabitants of Earth’s deep ocean regions (3– 5). No...

متن کامل

Compressed Liquid Densities for Binary Mixtures at Temperatures from 280- 440K at Pressures up to 200 MPa

A method for predicting liquid densities of binary mixtures from heat of vaporization and liquid densityat boiling point temperature (ΔHvap and n b ρ ) as scaling constants, is presented. B2(T) follows a promisingcorresponding-states principle. Calculation of α(T) and b(T), the two other temperature-dependentconstants of the equation of state, are made possible by scaling. As a result ΔHvap and...

متن کامل

Evaluation of disintegration properties of orally rapidly disintegrating tablets using a novel disintegration tester.

This report describes a new disintegration tester that can determine not only the disintegration time of orally rapidly disintegrating tablets (ODT), but also the disintegration behavior and mechanism. Using the tester, the disintegration properties of the tablets prepared in a previous study were examined. The purpose of this study is to confirm the utility of the tester as an instrument for e...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 108  شماره 

صفحات  -

تاریخ انتشار 2003