Pulmonary deposition of nebulised amiloride in cystic fibrosis: comparison of two nebulisers.

نویسندگان

  • S H Thomas
  • M J O'Doherty
  • A Graham
  • C J Page
  • P Blower
  • D M Geddes
  • T O Nunan
چکیده

BACKGROUND Preliminary evidence suggests that regular inhalation of nebulised amiloride reduces sputum viscoelasticity, increases the clearance of sputum by mucociliary mechanisms and by coughing and reduces the rate of deterioration in lung function in patients with cystic fibrosis. These effects depend on adequate delivery of amiloride to the airways. This study was performed to quantify and compare pulmonary deposition of amiloride produced by two different nebuliser systems. METHODS The pulmonary deposition of nebulised amiloride (1 mg in 3 ml saline) was measured in eight patients with cystic fibrosis when given via a jet (System 22 with CR 60 compressor) and an ultrasonic (Fisoneb) nebuliser. Human serum albumin labelled with technectium-99m was used as an indirect marker for amiloride and its deposition in the lung was detected with a gamma camera. RESULTS Amiloride inhalation caused no side effects or changes in spirometric indices. The mean (SD) total pulmonary amiloride deposition was 57 (24) micrograms with the System 22 and 103 (53) micrograms with the Fisoneb nebuliser. Pulmonary deposition was completed more rapidly with the Fisoneb (4-5 minutes) than with the System 22 nebuliser (7-8 minutes) and the Fisoneb was preferred by the patients. CONCLUSIONS Both nebulisers appeared to deliver adequate amounts of amiloride to the lungs, but treatment with the Fisoneb nebuliser was quicker, more efficient, and more acceptable to the patients. Of the two nebulisers assessed, the Fisoneb would be preferred for clinical trials.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of amiloride and saline on nasal mucociliary clearance and potential difference in cystic fibrosis and normal subjects.

BACKGROUND Mucociliary clearance is an important component of pulmonary defence. Maximum clearance is thought to depend on an optimal depth of the sol layer, allowing the most efficient interaction between the cilia and the overlying mucus layer. Sodium absorption, the major ion transport in human airways, is thought to be important in the regulation of the depth of the sol layer. In the airway...

متن کامل

A widely available method for the assessment of aerosol delivery in cystic fibrosis.

Whilst nebulisers are commonly used in the treatment of cystic fibrosis (CF), nebulised aerosol lung deposition in individual patients is not routinely assessed in clinical practice. The present study was designed to evaluate whether a comparative measurement of aerosol lung deposition from nebulisers using a widely available scintigraphic method could be employed to assist the selection of the...

متن کامل

Improvement of nebulised antibiotic delivery in cystic fibrosis.

AIM To investigate deposition patterns and to assess the delivery rate of two nebuliser systems in children with cystic fibrosis (CF). METHODS Thirty three children with CF on regular treatment with nebulised antibiotics had radioisotope scans performed using technetium-99m labelled aerosol antibiotic generated by a Ventstream nebuliser (median mass diameter (MMD), 3.3 microm; delivery rate, ...

متن کامل

Comparison of lung deposition of colomycin using the HaloLite and the Pari LC Plus nebulisers in patients with cystic fibrosis.

AIM To examine the effectiveness of delivery of nebulised colistin by the HaloLite nebuliser compared to the Pari LC Plus in patients with cystic fibrosis. METHODS Randomised crossover trial of 15 patients aged >6 years. Inhalation of one mega unit of colistin in 3 ml diluent, labelled with technetium-99m DTPA, was used to assess lung deposition. The Pari was nebulised to dryness and one butt...

متن کامل

Which apparatus for inhaled pentamidine? A comparison of pulmonary deposition via eight nebulisers.

Aerosolised pentamidine 300 mg in 5 or 6 ml solution was administered via 8 different nebuliser systems to 12 patients with acquired immunodeficiency syndrome. Using 99mTc human serum albumin as an indirect marker for pentamidine, pulmonary, extrapulmonary (gastric and oropharyngeal) and alveolar deposition of pentamidine were measured using a gamma camera. Side effects (visual analogue scales)...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Thorax

دوره 46 10  شماره 

صفحات  -

تاریخ انتشار 1991