A Study of Success Rate of Miniscrew Implants as Temporary Anchorage Devices in Singapore
نویسندگان
چکیده
Objective. To find out the success rate of miniscrew implants in the National Dental Centre of Singapore (NDCS) and the impact of patient-related, location-related, and miniscrew implant-related factors. Materials and Methods. Two hundred and eighty-five orthodontic miniscrew implants were examined from NDCS patient records. Eleven variables were analysed to see if there is any association with success. Outcome was measured twice, immediately after surgery prior to orthodontic loading (T1) and 12 months after surgery (T2). The outcome at T2 was assessed 12 months after the miniscrew's insertion date or after its use as a temporary anchorage device has ceased. Results. Overall success rate was 94.7% at T1 and 83.3% at T2. Multivariate analysis revealed only the length of miniscrew implant to be significantly associated with success at both T1 (P = 0.002) and T2 (P = 0.030). Miniscrew implants with lengths of 10-12 mm had the highest success rate (98.0%) compared to other lengths, and this is statistically significant (P = 0.035). At T2, lengths of 10-12 mm had significantly (P = 0.013) higher success rates (93.5%) compared to 6-7 mm (76.7%) and 8 mm (82.1%) miniscrew implants. Conclusion. Multivariate statistical analyses of 11 variables demonstrate that length of miniscrew implant is significant in determining success.
منابع مشابه
Corrigendum to “A Study of Success Rate of Miniscrew Implants as Temporary Anchorage Devices in Singapore”
[This corrects the article DOI: 10.1155/2015/294670.].
متن کاملMiniscrew implants as temporary anchorage devices in orthodontics: a comprehensive review.
In recent times, the use of miniscrew implants to obtain absolute anchorage has gained momentum in clinical orthodontics as rigid anchorage modality. Miniscrew implants offers many advantages when used as temporary anchorage devices like, easy placement and removal, immediate loading, can be used in a variety of locations, provide absolute anchorage, economic and requires less patient cooperati...
متن کاملSecond Molar Uprighting with Temporary Anchorage Devices: A Finite Element Study
BACKGROUND AND OBJECTIVE: Premature loss of mandibular first molar is a common problem in adults. Mesial tipping of second molar may occur in this situation. Various orthodontic mechanics have been proposed for molar uprighting. The aim of this study was to compare four methods of molar uprighting using Finite Element Analysis(FEM). METHODS: In first model of this finite element study, a 0.019...
متن کاملEvaluation of primary stability of innovated orthodontic miniscrew system (STS): An ex-vivo study
BACKGROUND Stability is determined as one of the requirements in use of Temporary Anchorage Devices (TAD) in orthodontics. Miniscrew has been a widely used Bone Anchor. Compared with mini-implant that necessitates osseointegration; mechanical retention is a determining factor for primary stability of miniscrew. Studies investigated various ways to increase primary stability. The aim of this stu...
متن کاملInfluence of inter-root septum width on mini-implant stability
Objective: The purpose of this study was to evaluate the influence of the inter-radicular septum width in the insertion site of self-drilling mini-implants on the stability degree of these anchorage devices. Methods: The sample consisted of 40 mini-implants inserted in the inter-radicular septum between maxillary second premolars and first molars in 21 patients to provide skeletal anchorage for...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
دوره 2015 شماره
صفحات -
تاریخ انتشار 2015