Analysis of 4D CT cine images for the characterization of organ motion due to breathing

نویسندگان

  • Maria Francesca Spadea
  • Marta Peroni
  • Marco Riboldi
  • Guido Baroni
  • George TY Chen
  • Gregory Sharp
چکیده

A semi-automatic procedure to correlate the motion of lung tumor points in 4D-CT images with a respiratory surrogate signal is presented. Data analysis was performed to characterize of the robustness of external/internal correlation properties in the clinical framework of gated radiotherapy treatments. A cross-correlation based algorithm was implemented to perform template matching for tracking the spatial movement of tumor’s points in 6 patients. A graphical interface was developed to allow users to navigate through un-binned CT images. The detected internal movement of features in 3D was then retrospectively synchronized with the RPM signal, and the correlation index R was computed. Results also include the range of motion of selected points, and the prediction error. The developed procedure allowed a fast analysis for external/internal correlation of lung anatomy. The study is generally relevant for all the treatments in which organ motion compensation and control is an issue.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An automated method for comparing motion artifacts in cine four‐dimensional computed tomography images

The aim of this study is to develop an automated method to objectively compare motion artifacts in two four-dimensional computed tomography (4D CT) image sets, and identify the one that would appear to human observers with fewer or smaller artifacts. Our proposed method is based on the difference of the normalized correlation coefficients between edge slices at couch transitions, which we hypot...

متن کامل

Motion artifacts occurring at the lung/diaphragm interface using 4D CT attenuation correction of 4D PET scans

For PET/CT, fast CT acquisition time can lead to errors in attenuation correction, particularly at the lung/diaphragm interface. Gated 4D PET can reduce motion artifacts, though residual artifacts may persist depending on the CT dataset used for attenuation correction. We performed phantom studies to evaluate 4D PET images of targets near a density interface using three different methods for at...

متن کامل

Retrospective analysis of artifacts in four-dimensional CT images of 50 abdominal and thoracic radiotherapy patients.

PURPOSE To quantify the type, frequency, and magnitude of artifacts in four-dimensional (4D) CT images acquired using a multislice cine method. METHODS AND MATERIALS Fifty consecutive patients who underwent 4D-CT scanning and radiotherapy for thoracic or abdominal cancers were included in this study. All the 4D-CT scans were performed on the GE multislice PET/CT scanner with the Varian Real-t...

متن کامل

A Simulation Study on Patient Setup Errors in External Beam Radiotherapy Using an Anthropomorphic 4D Phantom

Introduction Patient set-up optimization is required in radiotherapy to fill the accuracy gap between personalized treatment planning and uncertainties in the irradiation set-up. In this study, we aimed to develop a new method based on neural network to estimate patient geometrical setup using 4-dimensional (4D) XCAT anthropomorphic phantom. Materials and Methods To access 4D modeling of motion...

متن کامل

Four-Dimensional Real-Time Cine Images of Wrist Joint Kinematics Using Dual Source CT with Minimal Time Increment Scanning

PURPOSE To validate the feasibility of real time kinematography with four-dimensional (4D) dynamic functional wrist joint imaging using dual source CT. MATERIALS AND METHODS Two healthy volunteers performed radioulnar deviation and pronation- supination wrist motions for 10 s and 4 s per cycle in a dual source CT scanner. Scan and reconstruction protocols were set to optimize temporal resolut...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009