Exhaled Breath Metabolomics for the Diagnosis of Pneumonia in Intubated and Mechanically-Ventilated Intensive Care Unit (ICU)-Patients
نویسندگان
چکیده
The diagnosis of hospital-acquired pneumonia remains challenging. We hypothesized that analysis of volatile organic compounds (VOCs) in exhaled breath could be used to diagnose pneumonia or the presence of pathogens in the respiratory tract in intubated and mechanically-ventilated intensive care unit patients. In this prospective, single-centre, cross-sectional cohort study breath from mechanically ventilated patients was analysed using gas chromatography-mass spectrometry. Potentially relevant VOCs were selected with a p-value < 0.05 and an area under the receiver operating characteristics curve (AUROC) above 0.7. These VOCs were used for principal component analysis and partial least square discriminant analysis (PLS-DA). AUROC was used as a measure of accuracy. Ninety-three patients were included in the study. Twelve of 145 identified VOCs were significantly altered in patients with pneumonia compared to controls. In colonized patients, 52 VOCs were significantly different. Partial least square discriminant analysis classified patients with modest accuracy (AUROC: 0.73 (95% confidence interval (CI): 0.57-0.88) after leave-one-out cross-validation). For determining the colonization status of patients, the model had an AUROC of 0.69 (95% CI: 0.57-0.82) after leave-one-out cross-validation. To conclude, exhaled breath analysis can be used to discriminate pneumonia from controls with a modest to good accuracy. Furthermore breath profiling could be used to predict the presence and absence of pathogens in the respiratory tract. These findings need to be validated externally.
منابع مشابه
Exhaled breath profiling for diagnosing acute respiratory distress syndrome
BACKGROUND The acute respiratory distress syndrome (ARDS) is a common, devastating complication of critical illness that is characterized by pulmonary injury and inflammation. The clinical diagnosis may be improved by means of objective biological markers. Electronic nose (eNose) technology can rapidly and non-invasively provide breath prints, which are profiles of volatile metabolites in the e...
متن کاملFactors Influencing Continuous Breath Signal in Intubated and Mechanically-Ventilated Intensive Care Unit Patients Measured by an Electronic Nose
INTRODUCTION Continuous breath analysis by electronic nose (eNose) technology in the intensive care unit (ICU) may be useful in monitoring (patho) physiological changes. However, the application of breath monitoring in a non-controlled clinical setting introduces noise into the data. We hypothesized that the sensor signal is influenced by: (1) humidity in the side-stream; (2) patient-ventilator...
متن کاملThe effect of a designed Care Plan on the incidence of aspiration in intubated patients: A randomized clinical trial
Background : Patients hospitalized in intensive care unit are at risk of aspiration and subsequent complications due to factors such as endotracheal tube, mechanical ventilation, and decreased level of consciousness. Aspiration of gastric residuals to the lung is one of the preventable lesions in patients who are feeding by tube and under mechanical ventilation.This study was conducted to deter...
متن کاملThe effect of Therapeutic Touch on Physiological Variables of Mechanically Ventilated Patients in Intensive Care Units
Background: Underlying diseases and aggressive procedures, such as different types of surgery and care, for patients with critical conditions in intensive care units (ICU) may be associated with physiological disorders. Objectives: This study intended to determine the effect of therapeutic touch on physiological variables of patients undergoing mechanical ventilation in ICU. Methods: This...
متن کاملEffect of Oral Drop Gastrolit (Zataria multiflora) on Gastric Residual Volume in Mechanically Ventilated Patients Hospitalized in the Intensive Care Units
Background: Proper nutritional support is one of the important caring aspects in patients who were hospitalized in ICU. Objective: This study was done to investigate Oral Drop Gastrolit effect on the gastric residual volume (GRV) in mechanically ventilated patients hospitalized in ICU. Methods: In this clinical trial, 50 mechanically ventilated patients were recruited using convenience sampli...