Use of the Cusum technique for evaluation of a CT-based navigation system for total knee replacement.

نویسندگان

  • Remy S Nizard
  • Raphael Porcher
  • Philippe Ravaud
  • Edouard Vangaver
  • Didier Hannouche
  • Pascal Bizot
  • Laurent Sedel
چکیده

Most of the early failures of total knee replacements are related to technical flaws. Conventional ancillary devices achieve good alignment in the frontal plane in only an average of 75% of total knee replacements. Computer-assisted surgery may improve the technical quality of implantation surgery. The aim of our study was to evaluate the use of computer-assisted surgery using a quality control process. Seventy-eight total knee arthroplasties were done with a CT-based computer-assisted surgery system. The outcomes studied were alignment of the lower limb, implant positioning, and operative time. The target for alignment was 180 degrees +/- 3 degrees. Cusum analysis showed that the three outcomes were controlled during the study. The cusum test identified any existing outliers. Because few data were available at the beginning of this study regarding computer-assisted surgery for total knee replacement, a randomized study was not relevant. However, a control of the procedure was mandatory. The cusum technique allowed continuous evaluation of the performance of the new procedure, and is a useful tool in assessing new technology. The results of this study showed that it is possible to do a randomized study to determine if computer-assisted surgery can improve the technical result of total knee replacement.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of Benson's relaxation technique on postoperative pain after total knee replacement in elder hospitalized patients in selected hospitals of kashan

Introduction: Pain is one of the most common problems in patients undergoing joint replacement. Except for medicinal treatments for pain relief, non-pharmacological methods of pain control, such as Benson's relaxation, cause more compromise with pain and reduce pain, fear and anxiety, and can tolerate it for the patient. The aim of this study was to determine the effect of Benson relaxation met...

متن کامل

Analysis of the Geometry of the Distal Femur and Proximal Tibia in the Osteoarthritic Knee: A 3D Reconstruction CT Scan Based Study of 449 Cases

    Background: The aim of this study is to evaluate the geometry of the distal femur and the proximal tibia in the osteoarthritic knee using 3D reconstructive CT scan imaging. Methods: 449 patients with knee osteoarthritis were treated surgically in our center with patient-specific technology total knee arthroplasty. Preoperatively, all the patients underwent a CT scan according to a standard ...

متن کامل

The evaluation of post-operative alignment in total knee replacement using a CT-based navigation system.

We compared the alignment of 39 total knee replacements implanted using the conventional alignment guide system with 37 implanted using a CT-based navigation system, performed by a single surgeon. The knees were evaluated using full-length weight-bearing anteroposterior radiographs, lateral radiographs and CT scans. The mean hip-knee-ankle angle, coronal femoral component angle and coronal tibi...

متن کامل

A Critical Review of Proximal Fibular Osteotomy for Knee Osteoarthritis

The surgical management of Knee Osteoarthritis (KOA), so far, mainly revolved around arthroscopic procedures,arthroplasty (total: TKA and unicompartmental: UKA) or high tibial osteotomy (HTO). Recently, another minimallyinvasive surgical treatment of proximal fibular osteotomy (PFO) has been proposed for the management of KOA. ThePFO has been found to be useful in the manageme...

متن کامل

Optimal overhaul–replacement policy for a multi-degraded repairable system sold with warranty

In this research, we study an optimal overhaul–replacement policy of a multi-degraded repairable system sold with a free replacement warranty. In the proposed replacement policy, a maintenance action and failure are dependent on a system degradation level and the system age, and hence the replacement model will provide more effective maintenance decisions. Failure of the system is modeled using...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical orthopaedics and related research

دوره 425  شماره 

صفحات  -

تاریخ انتشار 2004