Effectiveness of a Load-Imposing Device for Cyclic Stretching of Isolated Human Bronchi: A Validation Study
نویسندگان
چکیده
BACKGROUND Mechanical ventilation may induce harmful effects in the airways of critically ill patients. Nevertheless, the effects of cyclic stretching caused by repetitive inflation-deflation of the bronchial compartment have not been well characterized in humans. The objective of the present study was to assess the effectiveness of a load-imposing device for the cyclic stretching of human bronchi. METHODS Intact bronchial segments were removed from 128 thoracic surgery patients. After preparation and equilibration in an organ bath, bronchi were stretched repetitively and cyclically with a motorized transducer. The peak force imposed on the bronchi was set to 80% of each individual maximum contraction in response to acetylcholine and the minimal force corresponded to the initial basal tone before stretching. A 1-min cycle (stretching for 15 sec, relaxing for 15 sec and resting for 30 sec) was applied over a time period ranging from 5 to 60 min. The device's performance level was assessed and the properties of the stretched bronchi were compared with those of paired, non-stretched bronchi. RESULTS Despite the intrinsic capacities of the device, the targets of the tension adjustments remained variable for minimal tension (156-178%) while the peak force set point was unchanged (87-115%). In the stretched bronchi, a time-dependent rise in basal tone (P < .05 vs. non-stretched) was apparent after as little as 5 min of cyclic stretching. The stretch-induced rise in basal tone continued to increase (P < .01) after the stretching had ended. Only 60 min of cyclic stretching was associated with a significant (P < .05) increase in responsiveness to acetylcholine, relative to non-stretched bronchi. CONCLUSIONS Low-frequency, low-force, cyclic loading of human bronchi is associated with elevated basal tone and acetylcholine responsiveness. The present experimental model is likely to be a useful tool for future investigations of the bronchial response to repetitive stress during mechanical ventilation.
منابع مشابه
The impact of low-frequency, low-force cyclic stretching of human bronchi on airway responsiveness
BACKGROUND In vivo, the airways are constantly subjected to oscillatory strain (due to tidal breathing during spontaneous respiration) and (in the event of mechanical ventilation) positive pressure. This exposure is especially problematic for the cartilage-free bronchial tree. The effects of cyclic stretching (other than high-force stretching) have not been extensively characterized. Hence, the...
متن کاملEnhancing Performance of Infill Masonry With Skin reinforcement Subjected To Cyclic Load
Masonry infill has been widely used as building material due to its cost effectiveness and availability. The failure of these masonry infill walls during the past earthquakes have underscored the importance of ensuring the safety of the infill walls when it is subjected to lateral loads. In-plane and out of plane failures have been observed in many reinforced concrete framed building with maso...
متن کاملDevelopment and Validation of a Pilot Activity Load Index (PALI) based on NASA-TLX template
Abstract Introduction: Workload can be defined as the hypothetical construct that represents the cost incurred by a human operator to achieve a particular level of performance. Each job has specific needs and demands. The better measurement tool assessing that estimate the workload, it’s need to identify the requirements of a task, the circumstances under which it is performed, and the skills,...
متن کاملThe validation of one halitosis measuring device (Etiquette checker)
BACKGROUND AND AIM: Various measurement devices are available for detection of halitosis. For epidemiologic studies, it is necessary to use a portable and small device. This study aimed to investigation of correlation between measuring the device (Etiquette checker) with Halimeter. METHODS: One hundred volunteers (students and patients) participated in this study. The amount of volatile sulfur ...
متن کاملLoad Controlled Fatigue of AZ31B
With the expanding demand on application of magnesium alloys in automotive and aerospace industries, robust methods in fatigue characterization of commercially available magnesium alloys with high specific strength is anticipated. In this paper, rotating bending load controlled tests has been studied on specimens machined from an extrusion piece of AZ31B. Due to asymmetric and anisotropic behav...
متن کامل