High-Fidelity Modeling of Shift-Variant Focal-Spot Blur for High-Resolution CT
نویسنده
چکیده
Dedicated application-specific CT systems are popular solutions to high-resolution clinical needs. Some applications, such as mammography and extremities imaging, require spatial resolution beyond current capabilities. Thorough understanding of system properties may help tailor system design, acquisition protocols, and reconstruction algorithms to improve image quality. As resolution requirements increase, more accurate models of system properties are needed. Using a high-fidelity measurement model, we analyze the effects of shift-variant focal spot blur due to depth-dependence and anode angulation on image quality throughout the three-dimensional field of view of a simulated extremities scanner. A model of the shift-variant blur associated with this device is then incorporated into a Model-Based Iterative Reconstruction (MBIR) algorithm, which is then compared to FDK and MBIR with simpler blur models (i.e., no projection blur and shift-invariant projection blur) at select locations throughout the field of view. We show that shift-variant focal spot blur leads to location-dependent imaging performance. Furthermore, changing the orientation of the X-ray tube alters this spatial dependence. The analysis suggests methods to improve imaging performance based on specific image quality needs. For example, for small region of interest imaging, a transaxial X-ray tube orientation provides the best local image quality at a specific location, while for large objects an axial X-ray tube orientation provides better image quality uniformity. The results also demonstrate that image quality can be improved by combining accurate blur modeling with MBIR. Specifically, across the entire field of view, MBIR with shift-variant blur modeling yielded the best image quality, followed by MBIR with a shift-invariant blur model, MBIR with an identity blur model, and FDK, respectively. These results suggest a number of opportunities for the optimization of imaging system performance in the hardware setup, the imaging protocol, and the reconstruction approach. While the high-fidelity models used here are applied using the specifications of a dedicated extremities imaging system, the methods are general and may be applied to optimize imaging performance in any CT system.
منابع مشابه
Modeling Shift-Variant X-Ray Focal Spot Blur for High-Resolution Flat-Panel Cone-Beam CT.
Flat-panel cone-beam CT (CBCT) has been applied clinically in a number of high-resolution applications. Increasing geometric magnification can potentially improve resolution, but also increases blur due to an extended x-ray focal-spot. We present a shift-variant focal-spot blur model and incorporate it into a model-based iterative-reconstruction algorithm. We apply this algorithm to simulation ...
متن کاملThe effect of focal spot size on the spatial resolution of variable resolution X-ray CT scanner
Background: A variable resolution X-ray (VRX) CT scanner provides a great increase in the spatial resolution. In VRX CT scanners, the spatial resolution of the system and its field of view (FOV) can be changed according to the object size. One of the main factors that limit the spatial resolution of VRX CT scanner is the effect of the X-ray focal spot. Materials and Methods: A theoreti...
متن کاملInvestigation of the Spatial Resolution and Field of View with Change of Magnification in VRX CT
Introduction: Variable resolution x-ray (VRX) CT is a new type of CT that can image objects at various spatial resolutions. In a VRX CT scanner, the spatial resolution increases at the cost of reduction in the field of view (FOV). An important factor that limits the spatial resolution of the VRX CT is the effect of focal spot size. Also, the optimum magnification is different at each incident a...
متن کاملGeneralized Penalized Weighted Least-Squares Reconstruction for Deblurred Flat-Panel CBCT
An increase in achievable spatial resolution would enable application of flat-panel detector cone-beam CT (FPCBCT) in high-resolution applications, such as 3D breast and bone imaging. Improved reconstruction techniques exploiting more sophisticated models of noise and spatial resolution characteristics may provide such improvement. In this work, we propose a statistical model of measurement mea...
متن کاملHigh Fidelity System Modeling for High Quality Image Reconstruction in Clinical CT
Today, while many researchers focus on the improvement of the regularization term in IR algorithms, they pay less concern to the improvement of the fidelity term. In this paper, we hypothesize that improving the fidelity term will further improve IR image quality in low-dose scanning, which typically causes more noise. The purpose of this paper is to systematically test and examine the role of ...
متن کامل