Hybrid positron emission tomography (PET) and magnetic resonance (MR) scanners have become a reality in recent years with the benefits of reduced radiation exposure, reduction of imaging time, and potential advantages in quantification. Appropriate attenuation correction remains a challenge. Biases in PET activity measurements were demonstrated using the current MR based attenuation correction technique. We aim to investigate the impact of using standard MRAC technique on the clinical and research utility of PET/MR hybrid scanner for amyloid imaging. Methods: Florbetapir scans were obtained on 40 participants on a Biograph mMR hybrid scanner with simultaneous MR acquisition. PET images were reconstructed using both MR and CT derived attenuation map. Quantitative analysis was performed for both datasets to assess the impact of MR based attenuation correction to absolute PET activity measurements as well as target to reference ratio (SUVR). Clinical assessment was also performed by a nuclear medicine physician to determine amyloid status based on the criteria in the FDA prescribing information for florbetapir. Results: MR based attenuation correction led to underestimation of PET activity for most part of the brain with a small overestimation for deep brain regions. There is also an overestimation of SUVR values with cerebellar reference. SUVR measurements obtained from the two attenuation correction methods were strongly correlated. Clinical assessment of amyloid status resulted in identical classification as positive or negative regardless of the attenuation correction methods. Conclusions: MR based attenuation correction cause biases in quantitative measurements. The biases may be accounted for by a linear model, although the spatial by on October 29, 2017. For personal use only. jnm.snmjournals.org Downloaded from
منابع مشابه
Comparison of state-of-the-art atlas-based bone segmentation approaches from brain MR images for MR-only radiation planning and PET/MR attenuation correction
Introduction: Magnetic Resonance (MR) imaging has emerged as a valuable tool in radiation treatment (RT) planning as well as Positron Emission Tomography (PET) imaging owing to its superior soft-tissue contrast. Due to the fact that there is no direct transformation from voxel intensity in MR images into electron density, itchr('39')s crucial to generate a pseudo-CT (Computed Tomography) image ...
متن کاملImpact of MR-Based Attenuation Correction on Neurologic PET Studies.
UNLABELLED Hybrid PET and MR scanners have become a reality in recent years, with the benefits of reduced radiation exposure, reduction of imaging time, and potential advantages in quantification. Appropriate attenuation correction remains a challenge. Biases in PET activity measurements were demonstrated using the current MR-based attenuation-correction technique. We aimed to investigate the i...
متن کاملComputed tomography based attenuation correction in PET/CT: Principles, instrumentation, protocols, artifacts and future trends
The advent of dual-modality PET/CT imaging has revolutionized the practice of clinical oncology, cardiology and neurology by improving lesions localization and the possibility of accurate quantitative analysis. In addition, the use of CT images for CT-based attenuation correction (CTAC) allows to decrease the overall scanning time and to create a noise-free attenuat...
متن کاملAttenuation Effects of MR Headphones During Brain PET/MR Studies.
UNLABELLED PET/MR offers potential advantages over PET/CT that are currently under investigation. One of the challenges of PET/MR is attenuation correction, as there is no simple correlation between MR signal intensity and the attenuation of 511-keV photons detected in PET. Currently, dedicated MR sequences are used to segment voxels into categories that are then assigned a predetermined attenu...
متن کاملImprovement of attenuation correction in time-of-flight PET/MR imaging with a positron-emitting source.
UNLABELLED Quantitative PET imaging relies on accurate attenuation correction. Recently, there has been growing interest in combining state-of-the-art PET systems with MR imaging in a sequential or fully integrated setup. As CT becomes unavailable for these systems, an alternative approach to the CT-based reconstruction of attenuation coefficients (μ values) at 511 keV must be found. Deriving μ...