Preliminary analysis of the forces on the thoracic cage of patients with pectus excavatum after the Nuss procedure.
نویسندگان
چکیده
BACKGROUND The Nuss procedure corrects pectus excavatum using a pre-bent bar that generates stress on the chest wall. To investigate the biomechanical effects after the Nuss procedure, we designed a three-dimensional finite element analysis model to analyze the distribution of stress and strain induced in the chest wall. METHODS Three patients with pectus excavatum aged 8, 7, and 7 years, were enrolled in this study. The greatest upward displacements of their sternums after the operation were measured from computed tomography images and chest X-ray films. Based on these displacements, we constructed three finite element analysis models for analyzing biomechanical changes in the thoracic cage after the Nuss procedure. FINDINGS The simulation results indicated that greatest strain occurred at the third through seventh cartilages, especially where they join the sternum and ribs. A high bilateral stress distribution was also found over the backs of the third to the seventh ribs near the vertebral column. INTERPRETATION The stress and strain induced by the Nuss procedure can be analyzed using our finite element analysis model. Although the stress and strain may have some influence on chest and spine development, a more detailed finite element analysis model is recommended for future study to improve the accuracy of our simulation results.
منابع مشابه
First Iranian Experience of the Minimally Invasive Nuss Procedure for Pectus Excavatum Repair: A Case Series and Literature Review
Pectus excavatum is the most common congenital deformity of the chest wall. The most frequently used techniques include Ravitch (costochondral resection) and Nuss (minimally invasive pectus repair of pectus excavatum [MIRPE]). The Nuss technique includes using temporary metallic bars without costochondral resection to correct the chest wall deformity. Modified MIRPE can be learned easily and pe...
متن کاملMetal allergy to titanium bars after the Nuss procedure for pectus excavatum.
The Nuss procedure requires the placement of metal bars in the chest cage to repair pectus excavatum. Metal allergies are one of the complications associated with this procedure. Given that titanium is a biocompatible metal, it induces few allergic symptoms. Therefore, titanium bars are recommended for patients with metal sensitivity. We report the case of a 17-year-old boy with pectus excavatu...
متن کاملExercise improvement after pectus excavatum repair is not related to chest wall function.
OBJECTIVES In patients undergoing corrective surgery for pectus excavatum, there is evidence of improvement in cardiopulmonary function. It is unclear how much of this improvement is attributable to improved chest wall function. Thus, we observed changes in chest wall function in response to an incremental load exercise pre- and postoperatively. METHODS Using optoelectronic plethysmography, t...
متن کاملEarly results following the Nuss operation for pectus excavatum--a single-institution experience of 383 patients.
The prevalence of pectus excavatum is low but many patients are disabled from this thoracic deformity. The Nuss operation is a well-established surgical correction, however, until recently it has been rarely used in Europe. We have performed the Nuss operation regularly between 2001 and 2006 where a total of 383 patients were operated on for pectus excavatum. The indication for surgery was disa...
متن کاملThe Nuss procedure for pectus excavatum: evolution of techniques and early results on 322 patients.
BACKGROUND The Nuss procedure is a minimally invasive technique using a retrosternal bar to repair pectus excavatum. Although its technical simplicity and cosmetic advantages are remarkable, early applications have been limited to children with symmetrical pectus excavatum. We report a large single-institution experience including technical modifications to correct asymmetric configurations and...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical biomechanics
دوره 23 7 شماره
صفحات -
تاریخ انتشار 2008