The prognosis of implantable defibrillator patients treated with cardiac resynchronization therapy: comorbidity burden as predictor of mortality

نویسندگان

  • Dominic A.M.J. Theuns
  • Beat A. Schaer
  • Osama I.I. Soliman
  • David Altmann
  • Christian Sticherling
  • Marcel L. Geleijnse
  • Stefan Osswald
  • Luc Jordaens
چکیده

AIMS Comorbidity, such as myocardial infarction, diabetes, and renal failure, plays a pivotal role in the prognosis of a patient with arrhythmias. However, data on the prognostic impact of comorbiditiy in heart failure patients with cardiac resynchronization therapy and defibrillation (CRT-D) are scarce. The purpose of this study was to determine the impact of comorbidity on survival in CRT-D patients. METHODS AND RESULTS The study population consisted of 463 heart failure patients who received a CRT-D between 1999 and 2008 in Rotterdam and Basel. The Charlson comorbidity index (CCI) is often used as an adjusting variable in prognostic models. The Cox proportional hazards analysis was performed to determine the independent effect of comorbidity on survival. During a median follow-up of 30.5 months, 85 patients died. Mortality rates at 1 and 7 years were 6.3 and 32.3%. Cumulative incidence of implantable cardioverter defibrillator (ICD) therapy at 7 years was 50%, and death without ICD therapy was observed in 9% of patients. At least three comorbid conditions were observed in 81% of patients. Patients who died had a higher CCI score compared with those who survived (3.9 ± 1.5 vs. 2.9 ± 1.5; P < 0.001). An age-adjusted CCI score ≥ 5 was a predictor of mortality (hazard ratio 3.69, 95% CI 2.06-6.60; P < 0.001) independent from indication for ICD therapy, and from ICD interventions during the clinical course. CONCLUSION Comorbidity is often present in heart failure patients, and a high comorbidity burden was a significant predictor of mortality in CRT-D recipients. Comorbidity cannot predict appropriate ICD therapy. Death without prior ICD therapy occurs in a minor proportion of patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Medical Treatment of Heart Failure with Reduced Ejection Fraction – Aimed at Reducing Re- hospitalisations

Introduction The prognosis of patients with heart failure has significantly improved in the past decades with the advent of therapies such as angiotensinconverting enzyme (ACE) inhibitors, betablockers, mineralocorticoid receptor antagonists (MRAs), ivabradine, LCZ696 and with devices such as implantable cardioverterdefibrillator (ICD) and cardiac resynchronization therapy devices (CRT).[1] By ...

متن کامل

Cardiac resynchronization therapy: a meta-analysis of randomized controlled trials.

BACKGROUND Studies of cardiac resynchronization therapy in addition to an implantable cardioverter defibrillator in patients with mild to moderate congestive heart failure had not been shown to reduce mortality until the recent RAFT trial (Resynchronization/Defibrillation for Ambulatory Heart Failure Trial). We performed a meta-analysis including the RAFT trial to determine the effect of cardia...

متن کامل

Cardiac Resynchronization Therapy Reduces Ventricular Arrhythmias in Primary but Not Secondary Prophylactic Implantable Cardioverter Defibrillator Patients

Cardiac resynchronization defibrillators have been demonstrated to reduce both mortality and heart failure in patients with significant ventricular dysfunction and widened QRS. The influence of cardiac resynchronization therapy (CRT) on ventricular arrhythmias, however, is less certain. A systematic review of randomized controlled trials of more advanced heart failure populations with New York ...

متن کامل

Incidence and Costs Related to Lead Damage Occurring Within the First Year After a Cardiac Implantable Electronic Device Replacement Procedure.

BACKGROUND Inadvertent damage to leads for transvenous pacemakers, implantable cardioverter-defibrillators, and cardiac resynchronization therapy defibrillators is an important complication associated with generator-replacement procedures. We sought to estimate the incidence and costs associated with transvenous lead damage following cardiac implantable electronic device replacement. METHODS ...

متن کامل

Treatment of cardiogenic shock with left ventricular assist device combined with cardiac resynchronization therapy: A case report

Cardiogenic shock has a poor prognosis with established treatment strategies. We report a 62 years old man with heart failure exacerbating into refractory cardiogenic shock successfully treated with the combination of a percutaneous left ventricular assist device (LVAD) and subacute cardiac resynchronization therapy (CRT) implantable cardioverter-defibrillator device (CRT-D).

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2011