Hip arthrodesis in adolescents using external fixation.

نویسندگان

  • D M Scher
  • G K Jeong
  • A D Grant
  • W B Lehman
  • D S Feldman
چکیده

Between 1994 and 1998, seven adolescents underwent hip arthrodesis with the use of an external fixator. Mean time of follow-up was 24.0 months after surgery. The duration of fixation and time to fusion were 6.6 months (range, 5-9.5 months) and 8.0 months (range, 5.2-15 months), respectively. At most recent follow-up, there was a significant improvement in the mean modified Harris hip score, in which the maximum score is 91 points after omitting 9 points for hip range of motion and deformity, from 25.7 before surgery to 66.7 after surgery (p < 0.01). The advantages of this procedure include (i) the ease and accuracy of obtaining the proper position for fusion, (ii) the ability to lengthen the affected leg at the same time, (iii) the diminished likelihood of compromising future hip operations, and (iv) the ability to ambulate and bear weight throughout the treatment course. We recommend this method of hip arthrodesis with external fixation for patients with intractable hip pain necessitating this procedure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bone lengthening with extra-articular arthrodesis of the hip using external fixation

This is a case series of 11 children and adolescents who underwent femoral lengthening and percutaneous hip arthrodesis using a method of extra-articular joint compression in combination with callotasis. Clinical review indicated a significant improvement in physical function and psychological well-being. The average lengthening was 5.3 cm or 16% of the initial length. Complications were more f...

متن کامل

Shoulder arthrodesis using combined internal and external fixation: a review of 9 cases.

A technique of shoulder arthrodesis is presented. Fixation of the arthrodesis combines scapulohumeral half-frame Hoffmann external fixation and internal fixation using a cancellous screw. Cancellous bone autografts are packed at the site of arthrodesis. The functional results of nine cases are presented.

متن کامل

Salvage Procedures for Management of Prosthetic Joint Infection After Hip and Knee Replacements

BACKGROUND The increasing load placed by joint replacement surgery on health care systems makes infection, even with the lowest rates, a serious concern that needs to be thoroughly studied and addressed using all possible measures. METHODS A comprehensive review of the current literature on salvage procedures for recurrent PJIs using PubMed, EMBASE and CINAHL has been conducted. RESULTS Pro...

متن کامل

Hinged distraction of the adolescent arthritic hip.

From 1996 to 2000, 11 adolescents with hip joint arthritis secondary to osteonecrosis or idiopathic chondrolysis were treated with articulated hinged distraction arthroplasty. Indications for surgery were severe pain and limited ambulation. Charts and radiographs were reviewed. Clinical status was assessed preoperatively and at latest follow-up (mean 4.8 years after surgery) using criteria of p...

متن کامل

First Metatarsophalangeal Joint Arthrodesis: A Retrospective Comparison of Crossed-screws, Locking and Non-Locking Plate Fixation with Lag Screw

Background:Locking plate fixation is increasingly used for first metatarsophalangeal joint (MTP-I) arthrodesis. Still there is few comparable clinical data regarding this procedure. Methods:We retrospectively evaluated 60 patients who received an arthrodesis of the MTP-I between January 2008 and June 2010. With 20 patients each we performed a locking plate fixation with lag screw, arthrodesis w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of pediatric orthopedics

دوره 21 2  شماره 

صفحات  -

تاریخ انتشار 2001