Background Although videolaryngoscopes improve glottic visualization, their actual usefulness in intubation is not yet established. Aims The primary objective was to compare the ease of oral intubation with the use of 60° angled styletted endotracheal tube versus that performed over bougie inserted under videolaryngoscopic guidance. The secondary objectives were assessment of incidence of airway loss, hemodynamic changes, and time and number of attempts at intubation. Settings and Design This prospective randomized study was conducted in a tertiary care institution. Patients and Methods Seventy surgical patients requiring oral intubation were randomly allotted to Group S or Group B. Laryngoscopy was performed with Storz® C-MAC videolaryngoscope using D-Blade. In Group S, patients were intubated with a 60° angled stylletted endotracheal tube. In Group B, a bougie was introduced into the trachea and endotracheal tube was railroaded over the bougie. Statistical Analysis Used Chi-square test and independent sample t-test were used as applicable. Results The ease of intubation was significantly more in patients of Group S as compared to Group B (88.6% vs. 25.7%, respectively, P < 0.001) with significantly shorter intubation time (16.97 ± 7.91 vs. 77.43 ± 35.55 s, respectively, P < 0.001). The requirement of more than one attempt at intubation was significantly higher in Group B [57.1% vs. 5.7% P < 0.001, respectively]. Group B showed a significantly high mean arterial pressure at 1 and 3 min following intubation with no significant change in heart rate. Conclusion Use of 60° angled styletted endotracheal tube resulted in easier and faster intubation as compared to intubation over a bougie when used with C-MAC videolaryngoscope.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intubation without use of stylet for McGrath videolaryngoscopy in patients with expected normal airway

BACKGROUND During McGrath videolaryngoscope (VL) intubation, a styletted endotracheal tube maintaining an upward distal tip angle is recommended by some manufacturers. However, a styletted endotracheal tube can elicit rare but potentially serious complications. The purpose of this study was to demonstrate that a nonstyletted tube with exaggerated curvature would be noninferior to a styletted tu...

متن کامل

Stylet angulation for routine endotracheal intubation with McGrath videolaryngoscope

BACKGROUND The McGrath videolaryngoscope (VL) provides excellent laryngoscopic views, but directing an endotracheal tube can be difficult, and thus the routine use of a stylet is recommended. The goal of this study is to determine the appropriate angle (60° vs 90°) of the stylet when using the McGrath VL by comparing the time to intubation (TTI). METHODS One hundred and forty patients aged 19...

متن کامل

Comparison of the Success of Two Techniques for the Endotracheal Intubation with C-MAC Video Laryngoscope Miller Blade in Children: A Prospective Randomized Study

Background. Ease of endotracheal intubation with C-MAC video laryngoscope (VLS) with Miller blades 0 and 1 has not been evaluated in children. Methods. Sixty children weighing 3-15 kg with normal airway were randomly divided into two groups. Intubation was done with C-MAC VLS Miller blade using either nonstyletted endotracheal tube (ETT) (group WS) or styletted ETT (group S). The time for intub...

متن کامل

[Comparison of different stylets used for intubation with the C-MAC D-Blade® Videolaryngoscope: a randomized controlled study].

OBJECTIVE The angle of the C-MAC D-Blade® videolaryngoscope, which is used for difficult airway interventions, is not compatible with routinely used endotracheal tubes. METHODS A prospective randomized crossover study was performed comparing five intubation methods for use with standardized airways, including using different stylets or no stylet: Group HS, hockey-stick stylet; Group DS, D-bla...

متن کامل

Comparison between bougies and stylets for simulated tracheal intubation with the C-MAC D-blade videolaryngoscope.

BACKGROUND The C-MAC D-blade is a new, highly angulated, videolaryngoscope blade designed for use in patients with difficult airways. Directing a tracheal tube into the trachea with any indirect viewing laryngoscope can be difficult, even with a good view of the laryngeal inlet. OBJECTIVE To determine which introducing strategy is most suitable for use with the C-MAC D-blade videolaryngoscope...