Plating of proximal humeral fractures.

نویسندگان

  • Frank Martetschläger
  • Sebastian Siebenlist
  • Michael Weier
  • Gunther Sandmann
  • Philipp Ahrens
  • Karl Braun
  • Florian Elser
  • Ulrich Stöckle
  • Thomas Freude
چکیده

The optimal treatment for proximal humeral fractures is controversial. Few data exist concerning the influence of the surgical approach on the outcome. The purpose of this study was to evaluate the clinical and radiological outcomes of proximal humeral fractures treated with locking plate fixation through a deltopectoral vs an anterolateral deltoid-splitting approach. Of 86 patients who met the inclusion criteria, 70 were available for follow-up examination. Thirty-three patients were treated through a deltopectoral approach and 37 through an anterolateral deltoid-splitting approach. In all cases, open reduction and internal fixation with a PHILOS locking plate (Synthes, Umkirch, Germany) was performed. Clinical follow-up included evaluation of pain, shoulder mobility, and strength. Constant score and Disabilities of the Arm, Shoulder and Hand (DASH) score were assessed. A clinical neurological examination of the axillary nerve was also performed. Consolidation, reduction, and appearance of head necrosis were evaluated radiographically. After a mean follow-up of 33 months, Constant scores, DASH scores, and American Shoulder and Elbow Surgeons scores showed no significant differences between the groups. Clinical neurologic examination of the axillary nerve revealed no obvious damage to the nerve in either group. Deltopectoral and anterolateral detoid-splitting approaches for plate fixation of proximal humeral fractures are safe and provide similar clinical outcomes. The results of this study suggest that the approach can be chosen according to surgeon preference.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Is Loss of Fixation Following Locked Plating of Proximal Humeral Fractures Related to the Number of Screws and Their Positions in the Humeral Head?

The aim of the study was to examine the correlation between the chosen position of screws and the complications observed in patients who underwent locked plating of proximal humeral fractures. We evaluated radiographs of 367 patients treated by locked-plating for proximal humeral fractures. Radiographs were taken at one day, 6 weeks, 3 months and 6 months after surgery, and were analyzed for se...

متن کامل

Trends in the surgical treatment of proximal humeral fractures – a nationwide 23-year study in Finland

BACKGROUND Proximal humeral fractures are common osteoporotic fractures. Most proximal humeral fractures are treated non-surgically, although surgical treatment has gained popularity. The purpose of this study was to determine changes in the surgical treatment of proximal humeral fractures in Finland between 1987 and 2009. METHODS The study covered the entire adult (>19 y) population in Finla...

متن کامل

The Outcome of Proximal Humeral Locking Plates in the Management of Three and Four Part Proximal Humeral Fractures in Special Cohort of Young Patients in High Velocity Trauma

Background: Locking plate fixation provides satisfactory outcome following proximal humerus fractures. None of theprevious studies selectively evaluate the outcome in young patients. This study evaluates outcome of locking platesystem in the treatment of acute three- and four-part fractures in young patients.Methods: In this prospective study we included all patients who were less than 60 years...

متن کامل

The Mechanical Benefit of Medial Support Screws in Locking Plating of Proximal Humerus Fractures

BACKGROUND The purpose of this study was to evaluate the biomechanical advantages of medial support screws (MSSs) in the locking proximal humeral plate for treating proximal humerus fractures. METHODS Thirty synthetic left humeri were randomly divided into 3 subgroups to establish two-part surgical neck fracture models of proximal humerus. All fractures were fixed with a locking proximal hume...

متن کامل

Complications and Outcomes of Minimally Invasive Percutaneous Plating for Proximal Humeral Fractures

BACKGROUND The minimally invasive plate osteosynthesis (MIPO) technique using periarticular locking plates may be a good option for the repair of displaced proximal humeral fractures. However, axillary nerve complications related to this technique may be underestimated. The purpose of this study is to evaluate the outcomes of the minimally invasive plating, focusing on the complications. METH...

متن کامل

PHILOS Plate: Is it the Panacea for all Proximal Humerus Fractures?

Proximal humerus fractures are common and have a bimodal age distribution. Fracture-dislocations in younger patients result from highenergy trauma and most surgeons attempt open reduction and internal fixation, if at all possible. Osteoporotic fractures in elderly patients are commonly associated with low-energy trauma such as groundlevel falls and most are minimally displaced, impacted fractur...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Orthopedics

دوره 35 11  شماره 

صفحات  -

تاریخ انتشار 2012