Sub - Slab Depressurization Demonstration in Polk County
نویسندگان
چکیده
Six slab-on-grade houses in Polk County, Florida, with indoor radon levels between 19 and 80 pCi/1 were mitigated using sub-slab depressurization systems. With the compacted, moist soil fill under the slabs, sufficient sub-slab communications were difficult to establish. Increasing the suction pit size and using more powerful fans improved the strength of the pressure fields within 3 to 8 m of the suction holes but did little to extend them beyond this radius. The most effective means for extending the field was found to be installing additional suction holes (depressurized by the same fan) in locations where the pressure field was the weakest. Suction holes were placed both in centralized and in near-perimeter locations reached either by interior slab holes or through holes in the exterior stem wall. Indoor radon levels were measured using 2-day charcoal canisters, continuous radon monitors, and long-term (3 mo-1 yr) alpha track detectors. This paper has been reviewed in accordance with the U.S.Environmenta1 Protection Agency's peer and administrative review policies and approved for presentation and publication.
منابع مشابه
Management of Radon Data in the State of Ohio, U.S.A
The objective of this research paper is to create a public awareness in understanding the radon gas problem, discuss efficient data management methods and analyses of indoor radon gas concentrations, and mitigate the indoor radon gas concentrations to below acceptable level in the state of Ohio. The Ohio Radon Information System (ORIS) is a compendium of five databases or modules, viz. the “Hom...
متن کاملA Computer Program for Asd System Design Applications
Many practical applications for reducing elevated indoor radon concentrations depends on the utilization of active soil depressurization (ASD) systems such as the Sub-Slab Depressuirzation system. Applications of these systems for radon mitigation in large structures such as schools, hospitals and commercial offices are significantly more complicated than applications in residential structures ...
متن کاملSub-slab Pressure Field Extension in Schools and Other Large Buildings
The most direct method of projecting or measuring the performance of an active soil depressurization (ASD) system is to measure the strength and extent of the pressure field established under the slab. The pressure field extension (PFE) can be determined during diagnostics to help design an ASD system and following installation to ascertain system performance. In schools , and other large build...
متن کاملEvaluation of Air Quality in Buildings Located Above TCE and Chloroform Contaminated Plume - A Field Study
Vapor intrusion (VI) has been recognized since the 1990s as a potential pathway of concern at contaminated sites. VI is the migration of volatile organic compounds (VOCs) from the subsurface soils into overlying buildings. The major sources of organic vapors are waste disposal sites (landfills), contaminated old industrial sites, contaminated subsurface soils, and contaminated groundwater. The ...
متن کاملModeling of the Sub-slab Depressurization (ssd) Radon Mitigation Systems for Large Structures
There are several Active Soil Depressurization (ASD) computer based models that have been specifically designed and calibrated for residential structure ASD system applications and mitigation practices. Large structures encountered in large buildings are significantly different than residential structures and consequently different treatments are required. Considerations for substantially large...