The noise of coated cantilevers.
نویسندگان
چکیده
In atomic force microscopy, cantilevers with a reflective coating are often used to reduce optical shot noise for deflection detection. However, static AFM experiments can be limited by classical noise and therefore may not benefit from a reduction in shot noise. Furthermore, the cantilever coating has the detrimental side-effect of coupling light power fluctuations into true cantilever bending caused by time-varying thermal stresses. Here, we distinguish three classes of noise: detection, force, and displacement noise. We discuss these noises with respect to cantilever coating in the context of both static and dynamic AFM experiments. Finally, we present a patterned cantilever coating which reduces the impact of these noises.
منابع مشابه
Improved atomic force microscopy cantilever performance by partial reflective coating
Optical beam deflection systems are widely used in cantilever based atomic force microscopy (AFM). Most commercial cantilevers have a reflective metal coating on the detector side to increase the reflectivity in order to achieve a high signal on the photodiode. Although the reflective coating is usually much thinner than the cantilever, it can still significantly contribute to the damping of th...
متن کاملFrequency dependence of viscous and viscoelastic dissipation in coated micro-cantilevers from noise measurement.
We measure the mechanical thermal noise of soft silicon atomic force microscope cantilevers. Using an interferometric setup, we obtain a resolution down to 10(-14) m Hz(-1/2) on a wide spectral range (3-10(5) Hz). The low frequency behavior depends dramatically on the presence of a reflective coating: almost flat spectra for uncoated cantilevers versus a 1/f like trend for coated ones. The addi...
متن کاملMagnetostriction-driven cantilevers for dynamic atomic force microscopy
An actuation mode is presented to drive the mechanical oscillation of cantilevers for dynamic atomic force microscopy. The method is based on direct mechanical excitation of the cantilevers coated with amorphous Fe–B–N thin films, by means of the film magnetostriction, i.e., the dimensional change in the film when magnetized. These amorphous magnetostrictive Fe–B–N thin films exhibit soft magne...
متن کاملThe stochastic dynamics of micron and nanoscale elastic cantilevers in fluid: fluctuations from dissipation
The stochastic dynamics of micron and nanoscale cantilevers immersed in a viscous fluid are quantified. Analytical results are presented for long slender cantilevers driven by Brownian noise. The spectral density of the noise force is not assumed to be white and the frequency dependence of the noise force is determined from the fluctuation-dissipation theorem. The analytical results are shown t...
متن کاملMechanical and thermal effects of laser irradiation on force microscope cantilevers
In an optical lever set-up one or two modulated laser beams of 0,1 to 6 mW modulation amplitude at a wavelength of 670 nm were focused at uncoated and gold-coated microfabricated cantilevers. The motion of the levers was analyzed by an optical lever set-up. The mechanical resonance (30 to 60 kHz) of the cantilevers was excited by the modulated light both in air and under vacuum conditions (10 6...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Nanotechnology
دوره 23 2 شماره
صفحات -
تاریخ انتشار 2012