A clinical trial for the final cementation of crowns and bridges with a reinforced zinc oxide and eugenol cement, a polyacrylic acid cement and a zinc phosphate cement was made over a 3-year period. The study involved 441 patients for whom 547 bridges and 162 single restorations were cemented. The patients were recalled at 6-month intervals for the duration of the study and the restorations were examined for looseness. Of the 547 bridges 520 remained firmly cemented to the abutment teeth. Of 1,082 bridge retainers, 1,049 remained in position; success and failure by types of retainer will be the subject of a subsequent paper. Of the 162 single restorations 159 remained in place.
منابع مشابه
Retentiveness of dental cements used with metallic implant components.
There is limited dental literature evaluating the retentive capabilities of luting agents when used between metal components, such as cast metal restorations cemented onto machined metal implant abutments. This study compared the retentive strengths of 5 different classes of luting agents used to cement cast noble metal alloy crowns to 8-degree machined titanium cementable implant abutments fro...
متن کاملPractical clinical considerations of luting cements: A review.
The longevity of fixed partial denture depends on the type of luting cement used with tooth preparation. The clinician's understating of various cements, their advantages and disadvantages is of utmost importance. In recent years, many luting agents cements have been introduced claiming clinically better performance than existing materials due to improved characteristics. Both conventional and ...
متن کاملAssessment of the tensile strength of hexagonal abutments using different cementing agents.
The aim of this study was to assess the uniaxial tensile strength after thermal cycling in replicas of CeraOne abutments (abutment and coping sets), using four types of cements (n = 10). A zinc phosphate cement (Fosfato de Zinco/ SSW), a resin-modified glass ionomer cement (RelyX luting / 3M-ESPE), a zinc oxide-eugenol cement (ZOE/ SSW) and a zinc oxide cement without eugenol (TempBond NE/ KERR...
متن کاملTen years' clinical evaluation of three luting cements.
OBJECTIVE The aim of the present clinical longitudinal study was to observe, over 10 years, the prognosis of abutment teeth restored with fixed prostheses retained by glass ionomer luting cements and one conventional zinc phosphate cement. METHODS Three dentists prepared 135 abutment teeth in 61 patients to retain 81 fixed prostheses. The prostheses were retained by two glass ionomer luting c...
متن کاملTannin Fluoride Incorporated Luting Cement 207
phosphate, polycarboxylate, zinc oxide-eugenol and glass-ionomer products and the characteristics of these cements have been examined by several investigators2-5). In our previous investigation6), a decrease in compressive and diametral tensile strength was observed following 12 months immersion in distilled water with zinc phosphate, polycarboxylate and glass ionomer cements for luting, contai...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of dental research
دوره 56 10 شماره
صفحات -
تاریخ انتشار 1977