New calibrations of CR39 and Makrofol nuclear track detectors have been obtained using 158 A GeV Pb and In ions; a new method for the bulk etch rate determination, using both cone height and base diameter measurements was developed. The CR39 charge resolution based on the etch-pit base area measurement is adequate to identify nuclear fragments in the interval 7 ≤ Z/β ≤ 49. For CR39 the detection threshold is at REL ∼ 50 MeV cm g, corresponding to a nuclear fragment with Z/β ∼ 7. Base cone area distributions for Makrofol foils exposed to Pb ions have shown for the first time all peaks due to nuclear fragments with Z > 50; the distribution of the etched cone heights shows well separated individual peaks for Z/β = 78 ÷ 83 (charge pickup). The Makrofol detection threshold is at REL ∼ 2700 MeV cm g, corresponding to a nuclear fragment with Z/β ∼ 50. PACS: 29.40.Wk; 34.90.+q
منابع مشابه
Formation and growth of tracks in nuclear track materials
This paper reviews some aspects of solid-state nuclear track detectors (SSNTDs) and their applications in the radon and other research fields. Several geometrical models for the track growth given in the literature are described and compared. It is found that different models give close results for the dimensions of track openings. One of the main parameters that govern track formation is the b...
متن کاملMeasurement of bulk etch rate of LR 115 detector with atomic force microscopy
Equations for calculating track parameters have been proposed, which invariably involve the track etch rate Vt and the bulk etch rate Vb. The present study measured Vb for the LR115 solid-state nuclear track detector using atomic force microscopy (AFM). The detectors were partially masked using rubber cement and then etched in 2:5 N NaOH solution at 60◦C for time periods ranging from 5 to 40 mi...
متن کاملNuclear Track Detectors for Environmental Studies and Radiation Monitoring
Several improvements were made for Nuclear Track Detectors (NTDs) used for environmental studies and for particle searches. A new method was used to determine the bulk etch rate of CR39 and Makrofol NTDs. It is based on the simultaneous measurement of the diameter and of the height of etch-pit cones caused by relativistic heavy ions (158 A GeV Pb and In ions) and their fragments. The use of alc...
متن کاملBulk etch characteristics of colorless LR 115 SSNTD
The colorless LR 115 solid-state nuclear track detector (SSNTD) (from DOSIRAD) is based on cellulose nitrate and was first studied in view of its applicability in radiobiological experiments with alpha particles. In this paper, the bulk etch characteristics were studied. We first showed that the shape of the alpha-particle tracks are irregular with blurred contours under the optical microscope....
متن کاملEffect of Pre-gamma Irradiation on Cr-39*
The effect of pre-gamma irradiation on track density, bulk etch rate and light absorbance in CR-39 was investigated. CR-39 detectors were irradiated with gamma doses over a range of 0 to 280 kGy (0 to 28 Mrad). The detectors were overlaid with 0.77 mm of polyethylene and exposed to a known fluence of 252Cf spontaneous fission neutrons. All detectors were then etched in 6.25N sodium hydroxide so...
متن کامل